6-9
Electrical Servicing
(1) WATER TEMPERATURE SENSOR
Water Temperature Sensor
Sensor Inspection
Disconnect the water temperature sensor 2P con-
nector.
Measure the resistance between the water tempera-
ture sensor connector terminals.
Standard: 47.02 – 53.02 k
Ω
(25 ˚ C/77 ˚ F)
Replace the water temperature sensor if the resist-
ance is out of specification.
(1) PGM-FI 33P (BLACK) CONNECTOR
Meter Inspection
If the water temperature meter does not display,
inspect the following:
Disconnect the PGM-FI 33P (Black) connector and
water temperature meter 2P (Black) connector.
Check the continuity of the green terminal between
the ignition control module and water temperature
meter connector.
(1)
(1)
(1)
If there is no continuity, check the wire harness.
If there is continuity, check the water temperature
sensor.
If the water temperature sensor is normal, replace
the meter.