Ethernet Subagent
SNMP Configuration and Management Manual — 424777-006
14 -55
3009: ZESA-EVT-TCPIP-OBJ-AVAIL
ZESA-VAL-STATE-state
indicates the previous state of the TCP/IP process. The DDL AS clause associated
with this value is inserted in the message text following “previous state.”
ZESA-VAL-STATE-CONNECTED
indicates the current state of the TCP/IP process being monitored. The DDL AS
clause of this value (“connected,” defined above) appears in the message text
following “current state.”
ZEMS-VAL-NULL
indicates the type of subsystem defined event. Because the Ethernet Subagent
process has not defined this as a private event, the DDL AS clause “undefined”
always appears in the message text following “user content.”
Cause.
The subagent acquired or reacquired its connection to the configured TCP/IP
process (zesaTcpIpProcess).
Effect.
The MIB object values are rebuilt using SPI responses from the TCP/IP
process (zesaTcpIpProcess). When the update sequence is complete (as indicated by
zesaRefreshNow value = "autoDynamicRefresh (0)"), SNMP requests made against
the MIB objects will return current values.
Recovery.
Informational message only; no corrective action is needed.
Value of
ZEMS-TKN-STATE-PREVIOUS
Associated Text (DDL AS Clause)
ZESA-VAL-STATE-CONNECTED
“connected” indicates a normal operational
interface between the Ethernet Subagent and
the TCP/IP process it is monitoring.
ZESA-VAL-STATE-DISCONNECTED
“disconnected” indicates a nonoperational
state such that subagent function dependent
on the interface is not available.
ZESA-VAL-STATE-ENABLED
“enabled” indicates that the interface to the
TCP/IP resource has been set by an operator
such that the subagent immediately attempts
to restore it to a connected state.
ZESA-VAL-STATE-DISABLED
“disabled” indicates that the interface to the
TCP/IP resource has been taken out of
service explicitly by an operator setting the
zesaTcpIpState MIB object to “disabled.”
Summary of Contents for T9576G06
Page 24: ...Contents SNMP Configuration and Management Manual 424777 006 xxii Tables continued ...
Page 38: ...Part I Installing and Configuring SNMP SNMP Configuration and Management Manual 424777 006 ...
Page 140: ...Part II SCF for the SNMP Agent SNMP Configuration and Management Manual 424777 006 ...
Page 208: ...Part III Troubleshooting SNMP Configuration and Management Manual 424777 006 ...
Page 230: ...Part IV SNMP Subagents SNMP Configuration and Management Manual 424777 006 ...
Page 704: ...Part V Appendices SNMP Configuration and Management Manual 424777 006 ...
Page 778: ...Index SNMP Configuration and Management Manual 424777 006 Index 32 Special Characters ...