Trap Multiplexer Subagent/Manager
SNMP Configuration and Management Manual — 424777-006
12 -47
Related Operating System Event Messages
ZTMX-TKN-ERR-TEXT
contains text describing the error. This token is of type ZSPI-TYP-STRING.
Cause.
The Trap Multiplexer process experienced an internal or logic error.
Effect.
The process might or might not be able to recover from the error. If the primary
process cannot recover, its backup process should take over. If recovery is successful,
an event announcing the takeover is generated. If the error is not recoverable and the
process terminates, additional events are generated.
Recovery.
If the Trap Multiplexer primary and backup processes cannot recover from
the error, you can try restarting the subagent. Regardless of whether the Trap
Multiplexer is able to recover, contact your service provider and provide all relevant
information as follows:
•
Descriptions of the problem and accompanying symptoms
•
Details from the message or messages generated
•
Supporting documentation such as Event Management Service (EMS) logs
If your local operating procedures require contacting the GCSC, supply your system
number and the numbers and versions of all related products as well.
Sample Message
96-07-26 11:43:07 \COMM.$ZTMX TANDEM.TRAPMUX.D31 000105 Transient
Fault - SNMP-Trap-Multiplexer \COMM.$ZTMX,
event number: Process-Internal-Error,
fault type: Internal-error, error detail:
Cannot create socket
Related Operating System Event Messages
The following four Trap Multiplexer-related events are generated by the operating
system:
Process Trap Event
A “Process Trap” event is reported for a process whenever the process failed because
of a Guardian trap.
Process Abended Event
A “Process Abended” event is reported for a process whenever the process is abended
(stopped abnormally).
Process Suspended Event
A “Process Suspended” event is reported for a process whenever the process is
suspended.
Summary of Contents for T9576G06
Page 24: ...Contents SNMP Configuration and Management Manual 424777 006 xxii Tables continued ...
Page 38: ...Part I Installing and Configuring SNMP SNMP Configuration and Management Manual 424777 006 ...
Page 140: ...Part II SCF for the SNMP Agent SNMP Configuration and Management Manual 424777 006 ...
Page 208: ...Part III Troubleshooting SNMP Configuration and Management Manual 424777 006 ...
Page 230: ...Part IV SNMP Subagents SNMP Configuration and Management Manual 424777 006 ...
Page 704: ...Part V Appendices SNMP Configuration and Management Manual 424777 006 ...
Page 778: ...Index SNMP Configuration and Management Manual 424777 006 Index 32 Special Characters ...