Host Resources Subagent
SNMP Configuration and Management Manual — 424777-006
11 -43
MIB Objects
hrPrinterStatus
1.3.6.1.2.1.25.3.5.1.1
read-only
INTEGER {
other(1),
unknown(2),
idle(3),
printing(4),
warmup(5) }
The current state of
the printer
represented by the
entry.
One of the following
values:
other (in error or
unavailable)
idle
printing
unknown
If a printer is defined
and recorded by the
Spooler procedure
SPOOLERSTATUS2.
The value returned as
state
maps as follows to
hrPrinterStatus and
hrDeviceStatus values:
hrPrinter hrDevice
State Status Status
-------- -------- ---------
Spooler supervisor,
but the device does
not exit in reality, the
device has an entry in
hrDeviceTable and
hrPrinterTable. Its
device status is
defined as down, and
the printer status is
returned as unknown.
1 (device 3 2
waiting)
2 (device 4 2
busy)
3 (device 1 5
suspended)
4 (device 1 5
error)
5 (device 1 5
offline)
6 (printer 1 5
process
error
hrPrinterDetectedError
State
1.3.6.1.2.1.25.3.5.1.2
read-only
OCTET STRING
A description of any
error condition
existing for the
printer.
One of these values:
offline: 40
noPaper: 02
no error: 00
The last error value
returned by Spooler
procedure
SPOOLERSTATUS2.
Error codes 100 (device
not ready) and 104
(device does not respond)
are mapped to offline.
Error code 102 (paper
out) is mapped to
noPaper.
hrDiskStorageTable
Objects:
Entries describing
long-term storage
devices associated
with the system.
Refer to “hrDevice Group
Maintenance” later in this
section for information
about how entries are
maintained.
hrDiskStorageAccess
1.3.6.1.2.1.25.3.6.1.1
read-only
INTEGER {
readWrite(1),
readOnly(2) }
An indication of
whether the disk
represented by the
entry is readable
and writable, or only
readable. Optical
disks are always
read-only.
One of these values:
readWrite
readOnly
Guardian procedure
DEVICE_
GETINFOBYLDEV_.
For OSS: RW flag from
ZXCONFIG column 6.
Table 11-6. hrDevice Group Objects Supported by Host Resources Subagent’s
MIB
(page 5 of 9)
Object and Attributes
Definition
Format of Value
Derivation of Value
Summary of Contents for T9576G06
Page 24: ...Contents SNMP Configuration and Management Manual 424777 006 xxii Tables continued ...
Page 38: ...Part I Installing and Configuring SNMP SNMP Configuration and Management Manual 424777 006 ...
Page 140: ...Part II SCF for the SNMP Agent SNMP Configuration and Management Manual 424777 006 ...
Page 208: ...Part III Troubleshooting SNMP Configuration and Management Manual 424777 006 ...
Page 230: ...Part IV SNMP Subagents SNMP Configuration and Management Manual 424777 006 ...
Page 704: ...Part V Appendices SNMP Configuration and Management Manual 424777 006 ...
Page 778: ...Index SNMP Configuration and Management Manual 424777 006 Index 32 Special Characters ...