Host Resources Subagent
SNMP Configuration and Management Manual — 424777-006
11 -20
Starting and Stopping the Subagent
hrPartitionID
hrPartitionFSIndex
hrFSIndex
hrFSMountPoint
hrFSRemoteMountPoint
hrFSType
hrFSAccess
hrFSBootable
hrFSStorageIndex
hrFSLastFullBackupDate
hrFSLastPartialBackupDate
Because these values are relatively stable, the default stable refresh rate is
every 1440 minutes (24 hours). A value of 0 or less suppresses refreshing
these values. If the values are not refreshed, devices added after the subagent
completes its initialization are not recognized. Similarly, if a device is removed
from the system, an SNMP manager user is unaware of its removal because
the device is still represented in the subagent’s MIB.
If a configuration object is accessed from an SNMP manager within 30
seconds before the stable object timer expires, the subagent postpones
refreshing values until another cycle has passed. This minimizes SNMP
manager timeouts.
Whenever the values of configuration objects are refreshed, the values for MIB
objects in the hrSWRun and hrSWRunPerf groups are also refreshed.
The values of these hardware and software objects can be refreshed on
demand from an SNMP manager after the subagent is running by setting the
value of the object zhrmStableRefreshNow in the zhrmRefresh group.
-t
causes the subagent to enable Guardian file system and process monitoring. If
neither -t or -u is specified, monitoring of the Guardian personality is enabled,
and monitoring of the OSS personality is disabled.
-u
causes the subagent to enable NonStop Kernel Open System Services (OSS)
file system and process monitoring. By default, this option is disabled. If neither
-t or -u is specified, monitoring of the Guardian personality is enabled, and
monitoring of the OSS personality is disabled.
Note.
While the subagent refreshes configuration objects, SNMP managers
interacting with the subagent might experience a timeout. Simply resubmit these
requests after waiting a brief period. Large MIBs might require over a minute to be
refreshed.
Summary of Contents for T9576G06
Page 24: ...Contents SNMP Configuration and Management Manual 424777 006 xxii Tables continued ...
Page 38: ...Part I Installing and Configuring SNMP SNMP Configuration and Management Manual 424777 006 ...
Page 140: ...Part II SCF for the SNMP Agent SNMP Configuration and Management Manual 424777 006 ...
Page 208: ...Part III Troubleshooting SNMP Configuration and Management Manual 424777 006 ...
Page 230: ...Part IV SNMP Subagents SNMP Configuration and Management Manual 424777 006 ...
Page 704: ...Part V Appendices SNMP Configuration and Management Manual 424777 006 ...
Page 778: ...Index SNMP Configuration and Management Manual 424777 006 Index 32 Special Characters ...