![HP StorageWorks MSA 2/8 - SAN Switch Reference Manual Download Page 771](http://html.mh-extra.com/html/hp/storageworks-msa-2-8-san-switch/storageworks-msa-2-8-san-switch_reference-manual_165663771.webp)
spinFab
771
Fabric OS Version 3.1.x/4.1.x Reference Guide
-setfail mode
(V4.1.x only)
This parameter may be used to cause spinfab to mark
failing ports as bad. Specify a value 1 to mark failing
ports as BAD, specify a value of 0 to not mark failed ports
as bad. To minimize the impact on live fabrics this test
normally logs errors but does not set the port status to
FAILED. This parameter is provided to force the failing
ports to be marked as BAD in the same manner as other
diagnostics. In test or qualification environments without
live traffic this may be useful with large values of nmil. This
mode is disabled by default.
-domain value
(V4.1.x only)
The domain parameter is used to specify a specific remote
domain that the switch is connected to. The default is to
automatically determine the remote domain number. This
operand is optional.
Summary of Contents for StorageWorks MSA 2/8 - SAN Switch
Page 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Page 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Page 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Page 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Page 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Page 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Page 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...