Fabric OS Commands
266
Fabric OS Version 3.1.x/4.1.x Reference Guide
Reboot the switch, bypassing POST.
Synopsis
fastboot
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to reboot the switch, bypassing Power On Self Test (POST).
The reboot takes effect immediately as the switch resets and executes normal
power-on booting sequence. However, POST is skipped. This reduces boot time
significantly.
If POST has been disabled using the
diagDisablePost
command, then
fastboot
is the same as reboot. However, fastboot skips the POST on the
current reboot, while
diagDisablePost
skips POST on all future reboots
until cancelled by
diagEnablePost
.
Because
fastboot
reboots the CP a WARNING message and a confirmation
are displayed. The command only takes place if the user responds positively.
Note:
For the StorageWorks Core switch, the
fastboot
command will reboot both
logical switches and both CPs.
Operands
None.
fastboot
Summary of Contents for StorageWorks MSA 2/8 - SAN Switch
Page 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Page 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Page 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Page 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Page 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Page 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Page 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...