backPort
59
Fabric OS Version 3.1.x/4.1.x Reference Guide
■
ASIC errors along each path. The test will check for CRC and ENC errors for
each port used between the source and destination ports to help isolate
failures. It will also check that each member of every trunk group along the
path has sent or received at least one frame.
Note:
Area routing between user ports is not tested.
Operands
This command has the following operands:
-nframes num
Specify the number of frame sequences to send. The
default value is 100.
-ports list
Specify a list of user ports. The default value is all user
ports.
-lb_mode mode
Specify the loopback mode for source and destination
standard meanings. The default mode is 5. The valid
modes are:
0 cable loopback
1 plug loopback
2 external loopback (SERDES)
5 internal loopback (ASIC)
-fr_type type
Specify the frame types to send. The default type is 1.
The valid types are:
0 single frame
1
spinFab
frames
2
spinFab
1K frames
Summary of Contents for StorageWorks MSA 2/8 - SAN Switch
Page 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Page 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Page 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Page 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Page 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Page 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Page 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...