![HP StorageWorks MSA 2/8 - SAN Switch Reference Manual Download Page 683](http://html.mh-extra.com/html/hp/storageworks-msa-2-8-san-switch/storageworks-msa-2-8-san-switch_reference-manual_165663683.webp)
secfabricshow
683
Fabric OS Version 3.1.x/4.1.x Reference Guide
Displays security related fabric information.
Synopsis
secfabricshow
Availability
Admin
Release
V3.1.x and V4.1.x
Description
This command displays the security related information about the fabric.
The information displayed is as follows:
Note:
When security is enabled, this command can only be issued from the Primary
FCS switch. See “
Security Commands
” on page 941.
Operands
None.
secfabricshow
Role
Displays whether the switch is the Primary FCS, Backup FCS,
or Non FCS.
WWN
Displays the world wide name of the switch.
DId
Displays the Domain of the switch.
Status
Displays the security state of the switch.
Ready - This switch is in a stable state.
Busy - This switch is updating its security database.
Error - This switch's security database is inconsistent with the
Primary FCS.
Enet IP Addr
Displays the Ethernet IP address.
Name
Displays the switch name.
Summary of Contents for StorageWorks MSA 2/8 - SAN Switch
Page 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Page 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Page 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Page 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Page 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Page 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Page 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...