Fabric OS Commands
212
Fabric OS Version 3.1.x/4.1.x Reference Guide
Enable or disable diagnostics skip test flags.
Synopsis
diagskiptests [value | -show]
Availability
Admin
Release
V4.1.x
Description
Use this command to enable or disable the diagnostics skip test flags. The skip test
flags are saved in non-volatile memory and stay set until the next execution of
diagskiptests
.
The mode becomes active as soon as this command is executed. It does not require
a reboot to take effect.
The skip test flags are used to skip the execution of certain POST tests that may
prove hazardous to normal switch operation. The exact use of this flag is
determined by the post scripts and the specific test methods that are used.
Operands
This command has the following operands:
If no operand is specified the current value is displayed.
diagskiptests
value
Specify a bit mask for tests to be skipped.
-show
If specified or no value is given, the current skip test
flags will be displayed.
Summary of Contents for StorageWorks MSA 2/8 - SAN Switch
Page 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Page 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Page 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Page 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Page 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Page 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Page 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...