diagDisablePost
183
Fabric OS Version 3.1.x/4.1.x Reference Guide
Disable POST execution at reboot.
Synopsis
diagDisablePost
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to disable Power On Self Test (POST) execution at switch
reboot. This mode is saved in non-volatile memory and POST remains disabled
until it is enabled using the
diagEnablePost
command. A reboot is not
required for this command to take effect.
A switch rebooted without POST enabled issues the following
DIAG-POSTSKIPPED
error message:
0x10fc0c10 (tSwitch): Apr 6 13:24:42
Error DIAG-POST_SKIPPED, 3,
Skipped POST tests: assuming all ports are healthy,
Err# 0004
It is recommended that POST always be enabled to ensure the operational status
of the switch during the power on stage.
Operands