![HP StorageWorks MSA 2/8 - SAN Switch Reference Manual Download Page 185](http://html.mh-extra.com/html/hp/storageworks-msa-2-8-san-switch/storageworks-msa-2-8-san-switch_reference-manual_165663185.webp)
diagEnablePost
185
Fabric OS Version 3.1.x/4.1.x Reference Guide
Enable POST execution at next reboot.
Synopsis
diagEnablePost
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to enable POST execution at the next switch reboot. This mode
is saved in non-volatile memory and POST remains enabled until it is disabled
using the
diagDisablePost
command.
POST executed after a cold boot (a power cycle of the switch) runs longer than
POST executed after warm boot (executing
reboot
on a powered up switch).
The cold boot POST runs more data patterns during the
ramtest
.
Diagnostic POST divides into two separate phases, POST Phase I and POST
Phase II. POST Phase I mainly tests hardware soundness and POST Phase II tests
system functionality.
A reboot is not required for this command to take effect.
The following tests are executed during POST:
1. ramtest
2. portregtest
3. centralmemorytest
4. cmitest
5. camtest
6. portloopbacktest
diagEnablePost
Summary of Contents for StorageWorks MSA 2/8 - SAN Switch
Page 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Page 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Page 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Page 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Page 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Page 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Page 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...