Troubleshooting 3-13
7402
Both EDO and STD memory SIMMs installed
EDO SIMMs not supported
7403
Address did not map to bank
Failed MMC or SMC
7404
Address did not map to Group Configuration Table
Failed MMC or SMC
7405
Dual issue test failed
Failed monarch processor
7500
No RAM found
No SIMM pairs installed or they are not
seated
7501
Not enough good memory to run Operating System
Verify memory configuration using
PDC ME command
7502
Not enough good memory to run Boot Console Handler
Verify memory configuration using
PDC ME command. 256KB is required
7604
No bits set in test status
Contact the response center
7701
Using alternate memory configuration
Bad memory configuration detected
7702
Warning, abbreviated memory test
Fast Boot is Enabled
7703
SIMM loading warning
Contact the response center
7704
RAM bus warning
Verify memory configuration using
PDC ME command
7705
Good memory required to run Operating System is greater
than memory size
Verify memory configuration using
PDC ME command
7706
Mixed DRAMs.
Both EDO and standard memory are
present.
7800
PDT disabled warning
Verify PDT level with PDC PDT com-
mand
7800
PDT disabled halt
Verify PDT level with PDC PDT com-
mand
7801
Overwrite single bit error with multi-bit error in PDT
Check PDT level
7802
Duplicate PDT entry
Contact the response center
7803
EEPROM fault while updating PDT
Failed system board
7804
PDT table is full
Verify PDT level with PDC PDT com-
mand
7D00
HPMC memory error
HPMC in the memory system
7D01
HPMC I-cache parity error
I-cache parity error in the memory test
Table 3-9. Memory Troubleshooting (Continued)
Code
Description
Possible Cause
Summary of Contents for 3000/9x9KS Series
Page 14: ...xiv Contents E Sources of Information on the Web ...
Page 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Page 44: ...2 24 Install and Configuration ...
Page 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Page 120: ...5 6 Diagnostics ...
Page 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Page 136: ...6 16 Replaceable Parts ...
Page 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Page 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Page 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Page 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Page 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Page 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Page 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Page 302: ...8 114 SCSI and I O ...
Page 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Page 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Page 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Page 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Page 342: ...Memory Configuration Guidelines C 16 ...
Page 350: ...D 8 New System Features ...