Specifications A-1
A
System Specifications
This appendix contains the environmental, electrical, and physical specifications for the HP3000 and HP
9000 systems. Changes to the specifications for the HP9000 Kx50/Kx60/Kx70/Kx80 and HP3000/979KS
are noted in the table.
Table A-1. Environmental Specifications, HP 3000 and HP 9000
Description
Specification
Operating Temperature
5° to 40°
C (41° to 104°
F)
HP9000/Kx80 only 5° to 35°
C (41° to 91°
F)
Non-operating Temperature
-40° to 65°
C (-40° to 149°
F) (with no internal tape media device)
-40° to 45°
C (-40° to 113°
F) (with internal tape media device)
Temperature Rate of Change
20°
C (36°
F)/hr. (with no internal tape media device)
10°
C (18°
F)/hr. (with internal tape media device)
Over Temperature First Warning
35° C (95° F) Internal
Over Temperature Second Warning
with OS Shutdown
40° C (104° F) Internal
Over Temperature Hardware
Shutdown
43° C (109° F) Internal
Operating Humidity
15% to 80% RH non-condensing, max wet bulb
(at 26°
C (79°
F) with internal tape media device)
Non-operating Humidity
5% to 90% RH non-condensing (at 65°
C/149°
F) rate of change,
30% RH/hr.
HP 9000 Kx50/Kx60/Kx70/Kx80
and HP3000 979KS
5% to 80% RH non-condensing (at 65°
C/149°
F) rate of change,
30% RH/hr.
Operating Altitude
0 to 3.0 KM (0 to 10,000 ft) above sea level
Non-operating Altitude
0 to 4.5 KM (0 to 15,000 ft) above sea level
Heat Dissipation (maximum load)
4263 BTU/hr.
HP 9000 Kx50/Kx60/Kx70/Kx80
and HP3000 979KS
5846 BTU/hr.
Summary of Contents for 3000/9x9KS Series
Page 14: ...xiv Contents E Sources of Information on the Web ...
Page 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Page 44: ...2 24 Install and Configuration ...
Page 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Page 120: ...5 6 Diagnostics ...
Page 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Page 136: ...6 16 Replaceable Parts ...
Page 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Page 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Page 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Page 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Page 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Page 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Page 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Page 302: ...8 114 SCSI and I O ...
Page 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Page 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Page 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Page 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Page 342: ...Memory Configuration Guidelines C 16 ...
Page 350: ...D 8 New System Features ...