Display Codes 4-7
FLT
2x30 - 2x33
Instruction cache tag fault
FLT
2030
*Dcache alt. write word 0
FLT
2x40-2x43
Cache ierr fault
FLT
2x51 - 2x53
Data cache address line fault
FLT
2x61 - 2x62
Data cache data line fault
FLT
2x61 - 2x62
*Data cache RAM data fault
FLT
2x70
*Data cache DTAG fault
FLT
2x70 - 2x73
Data cache RAM fault
FLT
2x80 - 2x83
Data cache tag fault
FLT
2x91-2x93
Cache derr fault
FLT
2xA1-2xA2
PM cache RAM selftest fault
FLT
2xA3-2xA6
PM pointer selftest failure
FLT
2xA7-2xA8
PM CAM selftest failure
FLT
20B0
HPMC data cache parity fault
FLT
20B1
HPMC data cache parity fault in tag
FLT
20B1
*HPMC data cache parity fault in even tag
FLT
20B2
HPMC data cache parity fault in word 0
FLT
20B2
*HPMC data cache parity fault in odd tag
FLT
20B3
HPMC data cache parity fault in word 1
FLT
20B3
*HPMC data cache parity fault in even data
FLT
20B4
*HPMC data cache parity fault in odd data
FLT
20C3
HPMC Instruction cache word 1 parity fault
WARN
2xCO
Instruction cache parity error
WARN
2xC1
Instruction cache tag parity error
WARN
2xC2
Instruction cache word0 parity error
WARN
2xC3
Instruction cache word1 parity error
Table 4-5. Cache (Selftests and Diagnostics) Codes (Continued)
Ostat
Code
Description
(
Where x = CPU number
)
Descriptions preceded by an asterisk are applicable only for the following
systems: HP 9000 K250/K260/K450/K460/Kx70, HP VISUAL-IZE K260-
EG/K460-EG/K460-XP, and HP 3000 979KS.
Summary of Contents for 3000/9x9KS Series
Page 14: ...xiv Contents E Sources of Information on the Web ...
Page 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Page 44: ...2 24 Install and Configuration ...
Page 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Page 120: ...5 6 Diagnostics ...
Page 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Page 136: ...6 16 Replaceable Parts ...
Page 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Page 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Page 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Page 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Page 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Page 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Page 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Page 302: ...8 114 SCSI and I O ...
Page 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Page 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Page 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Page 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Page 342: ...Memory Configuration Guidelines C 16 ...
Page 350: ...D 8 New System Features ...