SCSI and I/O 8-25
1. Valid for single-ended drives only.
Table 8-13 HP A3353A J01, J4 and J5 Jumper Positions
Position/Pins
Jumper Function Descriptions
J01
B
1
1&2
Terminator Power supplied by Drive.
2
1
2&4
Terminator Power supplied from SCSI BUS.
1
1&3
Terminator Power supplied to SCSI BUS (Default)
1&2
1&3
2&4
Terminator Power supplied to SCSI BUS and Drive.
J4
01
1&2
Write Protect, jumper installed protects the entire disc drive. Default is NO
jumper.
02
3&4
Delayed Motor Start option. Default is NO jumper. Jumper installed, the spin-
dle motor start delay is 10 times the Target ID plus a maximum power up delay
of 3 sec.
03
5&6
Enable Motor Start. Default is NO jumper. Jumper installed will cause the
Target to wait for the START UNIT COMMAND from the SCSI HOST. No
jumper installed causes the unit to look at position #02.
04
7&8
Parity Disable. Default is NO jumper. Jumper installed causes parity checking
and error reporting to be disabled.
05
9&10
Reserved for factory use, default is no jumper.
06
11&12
Enable SCSI Signle-Ended Terminator. Jumper installed will enable the SCSI
Terminator. Jumper removed will disable the SCSI Terminator (default).
07
13&14
Reserved.
J5
01
1&2
SCSI Target ID 0. No jumper installed=0, jumper installed=1.
02
3&4
SCSI Target ID 1. No jumper installed=0, jumper installed=1.
03
5&6
SCSI Target ID 2. No jumper installed=0, jumper installed=1.
04
7&8
SCSI Target ID 3. No jumper installed=0, jumper installed=1.
05
9&10
Remote LED connector. Pin 9 is cathode (neg), Pin 10 is anode (pos). Pin 10 is
current limited through a 1K , 1/10W resistor.
06
11&12
Spindle Sync cable connector. Pin 11 is the SSREF+ or refernce Index signal,
Pin 12 is Gnd.
Summary of Contents for 3000/9x9KS Series
Page 14: ...xiv Contents E Sources of Information on the Web ...
Page 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Page 44: ...2 24 Install and Configuration ...
Page 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Page 120: ...5 6 Diagnostics ...
Page 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Page 136: ...6 16 Replaceable Parts ...
Page 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Page 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Page 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Page 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Page 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Page 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Page 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Page 302: ...8 114 SCSI and I O ...
Page 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Page 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Page 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Page 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Page 342: ...Memory Configuration Guidelines C 16 ...
Page 350: ...D 8 New System Features ...