8-34 SCSI and I/O
Table 8-15 J2 Option Connector
REMOTE
Open
Drive will operate as a Stand Alone Device. Jumpers should be used to select SCSI ID.
Shorted
Drive will operate as a Remote Device. The SCSI ID is set by applying remote logic (low true) to
the Unit Select pin sets.
AUTO SPIN-UP
Open
Disabled, drive will not spin up until initiator sends Start Unit Command. (With auto spin-up dis-
abled, the drive will return "not ready" to all commands except REQUEST SENSE, INQUIRY,
RESERVE, RELEASE, and START UNIT until the drive is ready for access.)
Shorted
Enabled, the drive will spin-up automatically at power on.
Table 8-16 J3 Option Connector Pin Definitions
Pinset
Upper Pin
Lower Pin
1
SCSI Unit Select 0: input, negative true
Open collector output: pulled high if Remote pinset is
shorted; pulled low if Remote pinset is open
2
SCSI Unit Select 1: input, negative true
Open collector output: pulled high if Remote pinset is
shorted; pulled low if Remote pinset is open
3
SCSI Unit Select 2: input negative true
Sync spindle output if Remote is shorted; pulled low if
Remote pinset is open
4
SCSI Unit Select 3: input negative true
Activity LED open collector output for external drive
activity LED; pulled low during initialization for
address selection
5
Reserved, must be open
Ground
6
+5Vdc output: may be used to power
external LED (there is a 261 Ohm current
limiting resistor in series with this pin)
Write Protect:
Open: the drive looks at Mode Page Header and
responds accordingly; default = NOT write protected.
Shorted: drive is forced into the Write protect mode.
Table 8-17 J3 U/Sel SCSI Address Settings
SCSI Address
U/Sel 3
U/Sel 2
U/Sel 1
U/Sel 0
0
O
O
O
O
1
O
O
O
S
2
O
O
S
O
3
O
O
S
S
4
O
S
O
O
5
O
S
O
S
6
O
S
S
O
7
O
S
S
S
8
S
O
O
O
9
S
O
O
S
10
S
O
S
O
11
S
O
S
S
12
S
S
O
O
13
S
S
O
S
14
S
S
S
0
15
S
S
S
S
O = Open (or false), S = Shorted (or true)
Summary of Contents for 3000/9x9KS Series
Page 14: ...xiv Contents E Sources of Information on the Web ...
Page 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Page 44: ...2 24 Install and Configuration ...
Page 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Page 120: ...5 6 Diagnostics ...
Page 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Page 136: ...6 16 Replaceable Parts ...
Page 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Page 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Page 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Page 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Page 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Page 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Page 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Page 302: ...8 114 SCSI and I O ...
Page 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Page 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Page 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Page 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Page 342: ...Memory Configuration Guidelines C 16 ...
Page 350: ...D 8 New System Features ...