4-12 Display Codes
FLT
722x
Bad Slave Memory Controller revision, x = SMC 0-3 on memory carrier 0
x = SMC 4-7 on memory carrier 1
FLT
7230
Slave Memory Controller failed to respond
FLT
7301
SIMM 0 bytes are not equal
FLT
7302
SIMM 1 bytes are not equal
FLT
7303
SIMM 0 data <> SIMM 1 data
FLT
7304
Unknown sizing compare fault
FLT
7305
Multi-bit error occurred during sizing
FLT
7306
Address test failed on bank
FLT
7307
ECC test failed on bank
FLT
7308
Single bit memory error caused HPMC
FLT
7401
No memory SIMMs installed
FLT
7402
Both EDO and STD memory SIMMs installed
FLT
7403
Address did not map to bank
FLT
7404
Address did not map to Group Configuration Table
FLT
7405
Dual issue test failed
FLT
7500
No RAM found
FLT
7501
Not enough good memory to run Operating System
FLT
7502
Not enough good memory to run Boot Console Handler
FLT
7604
No bits set in memory test status
FLT
7Fxy
x=SMC#, y=SIMM pair
WARN
7701
Using alternate memory configuration
WARN
7702
Memory not tested, initialized only
WARN
7703
SIMM loading warning
WARN
7704
RAM bus warning
WARN
7705
Good memory required to run Operating System is greater than memory size
WARN
7706
Both EDO and Standard DRAMs in system.
WARN
770F
Rev 1 Slave Memory Controller installed
TEST
C210
Memory hard reset
TEST
C220
Physical configuring memory
TEST
C230
Sizing memory banks
TEST
C240
Loading memory configuration from EEPROM
TEST
C250
Configuring memory interleave
TEST
C260
Testing memory interleave
TEST
C261
Testing first page of memory
TEST
C262
Testing dual issue
TEST
C263
Testing memory, write test
TEST
C264
Testing memory, read/write test
Table 4-10. Memory Subsystem Codes (Continued)
Ostat
Code
Description
Summary of Contents for 3000/9x9KS Series
Page 14: ...xiv Contents E Sources of Information on the Web ...
Page 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Page 44: ...2 24 Install and Configuration ...
Page 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Page 120: ...5 6 Diagnostics ...
Page 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Page 136: ...6 16 Replaceable Parts ...
Page 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Page 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Page 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Page 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Page 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Page 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Page 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Page 302: ...8 114 SCSI and I O ...
Page 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Page 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Page 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Page 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Page 342: ...Memory Configuration Guidelines C 16 ...
Page 350: ...D 8 New System Features ...