Rev. 1.10
16
October 23, 2020
Rev. 1.10
17
October 23, 2020
BC66F5652
2.4GHz RF Transceiver A/D Flash MCU
BC66F5652
2.4GHz RF Transceiver A/D Flash MCU
D.C. Characteristics
For data in the following tables, note that factors such as oscillator type, operating voltage, operating
frequency, pin load conditions, temperature and program instruction type, etc., can all exert an
influence on the measured values.
Operating Voltage Characteristics
Ta=-40°C~85°C
Symbol
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
V
DD
Conditions
V
DD
Operating Voltage – HXT
—
f
SYS
=f
HXT
=8MHz
1.9
—
3.6
V
f
SYS
=f
HXT
=12MHz
2.7
—
3.6
f
SYS
=f
HXT
=16MHz
3.3
—
3.6
Operating Voltage – HIRC
—
f
SYS
=f
HIRC
=8MHz
1.9
—
3.6
V
f
SYS
=f
HIRC
=12MHz
2.7
—
3.6
f
SYS
=f
HIRC
=16MHz
3.3
—
3.6
Operating Current Characteristics
Ta=-40°C~85°C
Symbol
Operation Mode
Test Conditions
Min.
Typ.
Max.
Unit
V
DD
Conditions
I
DD
SLOW Mode – LIRC
3V f
SYS
=32kHz
—
10
20
μA
SLOW Mode – LXT
3V f
SYS
=32768Hz
—
10
20
μA
FAST Mode – HIRC
3V f
SYS
=8MHz
—
1.0
1.5
mA
2.7V
f
SYS
=12MHz
—
1.2
2.2
mA
3V
—
1.50
2.75
3.3V f
SYS
=16MHz
—
3.2
4.8
mA
FAST Mode – HXT
3V f
SYS
=8MHz
—
1.0
1.5
mA
2.7V
f
SYS
=12MHz
—
1.2
2.2
mA
3V
—
1.50
2.75
3.3V f
SYS
=16MHz
—
3.2
4.8
mA
Note: When using the characteristic table data, the following notes should be taken into consideration:
1. Any digital inputs are setup in a non-floating condition.
2. All measurements are taken under conditions of no load and with all peripherals in an off state.
3. There are no DC current paths.
4. All Operating Current values are measured using a continuous NOP instruction program loop.