For indoor and outdoor use, suitable for Pool/Spa equipment control

ELECTRICAL RATING: 15 Amp Resistive, 1200 Watt Tungsten, 1 HP Motor Load - 120 Volt.

THIS DEVICE COMPLIES WITH FCC RULES PART 15.  Operation of this device is subject to the following two conditions

1. This device may not cause harmful interference. 2. This device must accept any interference that may be received,

including interference that may cause undesired operation. FCC rules prohibit adjustments to or modification of receiver and

transmitter circuitry except for replacing the remote control battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.

These Modular Radio Receivers are one half of a two part remote control system.

They operate as ordinary ON/OFF switches but they also respond to the signals of

a hand held transmitter - the other half of the system. The modules are designed for

indoor or outdoor use, and can handle a variety of switching applications, typical

around the house or farm. By the push of a button on the face of the transmitter, the

user is able to turn ON/OFF the connected load (lights, pump, etc.) from any remote

location*, safely and conveniently. In addition, a single transmitter can operate up to

four Receivers and is able to “teach” each Module a different code. (Transmitters are

sold separately). 
Model RC613 Receiver Module comes with its own manual ON/OFF button and 

it is intended to be installed at the location of the load. The connected load may be

turned ON/OFF using the hand-held transmitter or turned ON/OFF by pushing the red

button on the face of the Receiver.
Model RC613L Receiver Module is the same as RC613 except that it comes with

extra long (36 in.) leads.
Model RC615 Receiver Module is the same as the RC613L Module above, except

it has no manual ON/OFF button on its face. This Module is designed to be con-

nected to a timer and will override its pre-set program, without affecting the next

automatic operation. At-site control of the load is possible by the ON/OFF switch of

the timer.

* The open field range is 200 feet but depends on many factors like the age of the battery, proximity of

large metal objects, the location of the receiver and environmental conditions at the time of transmission.

1

IMPORTANT SAFETY INSTRUCTIONS

1. This Control must be installed by a qualified electrician, according to National and Local Electrical Codes. 
2. USE COPPER CONDUCTORS ONLY. If applicable, install this Control not less than 5 feet (3 meters for Canadian 

installations) of inside edge of pool or spa.

3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
4. For grounding of the installation, refer to section 250 and 680 of the National Electrical Code.
5. This Control should not operate any equipment which would cause bodily injury or property damage should it be 

activated unexpectedly.

6. Always disconnect electricity at main panel before servicing this Control or the equipment(s) connected to it. 

THIS CONTROL IS NOT TO BE USED AS A POWER DISCONNECT.

READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL

GENERAL INFORMATION

Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material 

contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.

IIN

NT

TE

ER

RM

MA

AT

TIIC

C IIN

NC

CO

OR

RP

PO

OR

RA

AT

TE

ED

D,,

SPRING GROVE, IL 60081-9698

http://www.intermatic.com

158RC12810

4

LIST OF AVAILABLE MODELS AND COMPONENTS

Model

Description

Specifications

RC613

Single Channel Receiver

15 Amp Resistive, 10 Amp (1200 Watt) Tungsten,

3-way switching module

1 HP Motor Load - 120 Volt

RC613L

Single Channel Receiver

15 Amp Resistive, 10 AMp (1200 Watt) Tungsten,

with 36 in. Lead

1 HP - 120 Volt, Single Pole Single Throw Contacts.

RC613R

Heavy-Duty Receiver

30 Amp Resistive - 120/240 Volt, 12.5 Amp (1500 Watt) 

and Relay Assembly

Tungsten - 120 Volt, 1.5 HP - 120 Volt, 3 HP - 240 Volt

Double Pole Single Throw Contacts..

RC615

Single Channel Receiver

15 Amp Resistive, 10 Amp (1200 Watt) Tungsten

Timer Override Module

1 HP Motor Load - 120 Volt

RC939

3 Channel Transmitter

Operates on 9 Volt Battery

P1103ME

24 hr. Timer

20A. Resistive, 120-240V; 10A. Tungsten 120V;

Mechanism Only

1.5 HP-120V, 3HP-240V; 50/60 Hz; DPST

Note: Remove and discard leads between clock terminals

1 and 3 (jumper only) and 5 and relay. Connect BLUE leads from

Receiver to clock terminals 3 and 5. Connect RED lead from Receiver 

to Relay coil. Connect BLACK and WHITE from Receiver to BLACK

and WHITE of Timer and to 120 volt supply. Connect 120V. load to 

BLUE and WHITE, cap unused leads. For 240V. connections follow

instructions supplied with timer.

TROUBLESHOOTING

Symptom

Possible Cause(s)

Corrective Action

No response to transmitter 

No power  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Turn ON power at main panel

signal at anytime

Loose connection(s) at receiver and/or load  . . . . . . . . . .Check connections

Transmitter battery dead  . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery

Receiver and transmitter are on two different codes  . . . .Change code settings (see page 3)

Faulty transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Check battery connections, replace transmitter

Faulty receiver  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace Receiver Module

No response to transmitter

Weak Battery  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery

signal some of the time

Appliance with brush type motor is in use  . . . . . . . . . . .Relocate appliance and/or connect to another circuit

Other radio transmitter (police, etc)

is operating nearby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Change master code of transmitter (See page 3)

Receiver is at edge of range . . . . . . . . . . . . . . . . . . . . . . .Mount Receiver closer or higher

Insufficient Range

Weak battery  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery

Antenna too close to ground  . . . . . . . . . . . . . . . . . . . . . .Relocate Receiver Module

Transmitter is held too close to ground  . . . . . . . . . . . . . .Hold transmitter at least 3 ft. above ground

Weak signal due to obstruction  . . . . . . . . . . . . . . . . . . . .Remote/relocate Receiver Module

Nuisance operation

Other radio transmitter (police, etc)

is operating nearby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Change master code of transmitter (See page 3)

Fluctuating supply voltage due to surge, etc.  . . . . . . . . .If frequent - install surge suppressor

Faulty receiver  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace receiver module

LIMITED ONE YEAR WARRANTY

If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace

it, at its sole option, the unit free of charge. This warranty applies only to the original purchaser and is not transferable. This warranty does not apply
to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to unautho-
rized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the
product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific legal
rights and you may have other rights that vary from state to state.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER
EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE
OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. 
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product,
along with proof of purchase, postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After
Sales Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000  http://www/intermatic.com  Please be sure to wrap the product 
securely when mailing to avoid shipping damage. 

Reviews: