Rev. 1.10
210
October 23, 2020
Rev. 1.10
211
October 23, 2020
BC66F5652
2.4GHz RF Transceiver A/D Flash MCU
BC66F5652
2.4GHz RF Transceiver A/D Flash MCU
EN is reset by hardware indicating that the calibration is complete.
The calibration function can only be activated in the Light Sleep state.
To get an accurate RF frequency, an appropriate VCO curve needs to be set by the VCO calibration
process. After power on, the device needs to do VCO calibration after setting the RF synthesizer
frequency. To initiate VCO calibration, the device needs to follow the procedure as shown below.
1. To select the RF channel (RF_CH): RF Carrier = 2 RF_CH (RF_CH = 0~100, channel
step: 1MHz)
2. Set ACAL_EN=1 to start VCO calibration.
3. Polling the ACAL_EN until it is cleared to 0 to detect the VCO calibration completion.
Standby State
After the device triggers the RF Transceiver TR/RX operations in the Light Sleep state, the RF
Transceiver starts the synthesizer and enters the standby state when the synthesizer is stable. Then
the RF Transceiver starts normal TR/RX operations.
TX State
The RF Transceiver will enter the TX state in the following conditions.
1. Continuous mode: PRM_RX is set to 0, CE is set to 1 and TX FIFO is not empty.
2. Single strobe mode: PRM_RX is set to 0 and a TX command is received.
The RF Transceiver will stay in the TX state for transmission until a complete TX packet is
transmitted, then it returns to the Light Sleep state. If CE=1 and TX FIFO is still not empty, the RF
Transceiver will automatically trigger next TX transaction.
The modulator and radio PA are active in the TX state.
RX State
The RF Transceiver will enter the RX state in the following conditions which are all in the
continuous mode.
1. PRM_RX is set to 1 and CE is set to 1.
2. PRM_RX is set to 1 and a RX command is received. On receiving the RX command, CE will be
set to 1 automatically.
The system will stay in the RX state until an RX complete event happens, then the RF Transceiver
returns to the Light Sleep state. An RX complete event can be that an RX packet is successfully
received or an RX time out condition happens.
The demodulator, Radio LNA and Mixer are active in the RX state.
RF Channel Frequency and Data Rate
RF Channel Frequency
The RF Transceiver RF channel frequency is determined by the carrier frequency, the modulated
RF signal occupies a BW which is less than 1MHz at 125/250/500Kbps data rate. It operates in
a frequency ranges from 2400MHz to 2500MHz. The programmable resolution of RF channel
frequency is 1MHz. The RF_CH register defines the RF channel as the following formula:
fc= 2400 + RF_CH (MHz)
In order to communicate with each other, the RF_CH of both sides of the transceiver should be set
with the same value.