Rev. 1.10
154
October 23, 2020
Rev. 1.10
155
October 23, 2020
BC66F5652
2.4GHz RF Transceiver A/D Flash MCU
BC66F5652
2.4GHz RF Transceiver A/D Flash MCU
Bit 2
SRW:
I
2
C slave read/write flag
0: Slave device should be in receive mode
1: Slave device should be in transmit mode
The SRW flag is the I
2
C Slave Read/Write flag. This flag determines whether
the master device wishes to transmit or receive data from the I
2
C bus. When the
transmitted address and slave address is match, that is when the HAAS flag is set high,
the slave device will check the SRW flag to determine whether it should be in transmit
mode or receive mode. If the SRW flag is high, the master is requesting to read data
from the bus, so the slave device should be in transmit mode. When the SRW flag
is zero, the master will write data to the bus, therefore the slave device should be in
receive mode to read this data.
Bit 1
IAMWU:
I
2
C Address Match Wake-Up control
0: Disable
1: Enable
This bit should be set to 1 to enable the I
2
C address match wake up from the SLEEP or
IDLE Mode. If the IAMWU bit has been set before entering either the SLEEP or IDLE
mode to enable the I
2
C address match wake up, then this bit must be cleared to zero by
the application program after wake-up to ensure correction device operation.
Bit 0
RXAK:
I
2
C bus receive acknowledge flag
0: Slave receives acknowledge flag
1: Slave does not receive acknowledge flag
The RXAK flag is the receiver acknowledge flag. When the RXAK flag is “0”, it
means that a acknowledge signal has been received at the 9th clock, after 8 bits of data
have been transmitted. When the slave device in the transmit mode, the slave device
checks the RXAK flag to determine if the master receiver wishes to receive the next
byte. The slave transmitter will therefore continue sending out data until the RXAK
flag is “1”. When this occurs, the slave transmitter will release the SDA line to allow
the master to send a STOP signal to release the I
2
C Bus.
I
2
C Bus Communication
Communication on the I
2
C bus requires four separate steps, a START signal, a slave device address
transmission, a data transmission and finally a STOP signal. When a START signal is placed on
the I
2
C bus, all devices on the bus will receive this signal and be notified of the imminent arrival of
data on the bus. The first seven bits of the data will be the slave address with the first bit being the
MSB. If the address of the slave device matches that of the transmitted address, the HAAS bit in the
SIMC1 register will be set and an I
2
C interrupt will be generated. After entering the interrupt service
routine, the slave device must first check the condition of the HAAS and SIMTOF bits to determine
whether the interrupt source originates from an address match, 8-bit data transfer completion or
I
2
C bus time-out occurrence. During a data transfer, note that after the 7-bit slave address has been
transmitted, the following bit, which is the 8th bit, is the read/write bit whose value will be placed in
the SRW bit. This bit will be checked by the slave device to determine whether to go into transmit or
receive mode. Before any transfer of data to or from the I
2
C bus, the microcontroller must initialise
the bus, the following are steps to achieve this:
• Step 1
Set the SIM2~SIM0 bits to “110” and SIMEN bit to “1” in the SIMC0 register to enable the I
2
C
bus.
• Step 2
Write the slave address of the device to the I
2
C bus address register SIMA.
• Step 3
Set the SIME interrupt enable bit of the interrupt control register to enable the SIM interrupt.