2.4GHz RF Transceiver A/D Flash MCU
System Start Up Time Characteristics
Ta=-40°C~85°C
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
V
DD
Conditions
t
SST
System Start-up Time
Wake-up from Condition where f
SYS
is off
— f
SYS
=f
H
~f
H
/64, f
H
=f
HXT
—
128
—
t
HXT
— f
SYS
=f
H
~f
H
/64, f
H
=f
HIRC
—
16
—
t
HIRC
— f
SYS
=f
SUB
=f
LXT
—
1024
—
t
LXT
— f
SYS
=f
SUB
=f
LIRC
—
2
—
t
LIRC
System Start-up Time
Wake-up from Condition where f
SYS
is on
— f
SYS
=f
H
~f
H
/64, f
H
=f
HXT
or f
HIRC
—
2
—
t
H
— f
SYS
=f
SUB
=f
LXT
or f
LIRC
—
2
—
t
SUB
System Speed Switch Time
FAST to SLOW Mode or
SLOW to FAST Mode
— f
HXT
switches from
off → on
—
1024
—
t
HXT
— f
HIRC
switches from
off → on
—
16
—
t
HIRC
— f
LXT
switches from
off → on
—
1024
—
t
LXT
t
RSTD
System Reset Delay Time
Reset source from Power-on reset or
LVR Hardware Reset
— RR
POR
=5V/ms
42
48
54
ms
System Reset Delay Time
LVRC/WDTC/RSTC Register Software
Reset
—
—
System Reset Delay Time
Reset Source from WDT O
verflow
Reset —
—
14
16
18
t
SRESET
Minimum Software Reset Width to Reset —
—
45
90
120
μs
t
ACTV
ROM Activation Time – Wake-up from
Power Down Mode
—
—
32
—
64
μs
Note: 1. For the System Start-up time values, whether f
SYS
is on or off depends upon the mode type and the chosen
f
SYS
system oscillator. Details are provided in the System Operating Modes section.
2. The time units, shown by the symbols t
HIRC
etc. are the inverse of the corresponding frequency values as
provided in the frequency tables. For example t
HIRC
=1/f
HIRC
, t
SYS
=1/f
SYS
etc.
3. If the LIRC is used as the system clock and if it is off when in the SLEEP Mode, then an additional LIRC
start up time, t
START
, as provided in the LIRC frequency table, must be added to the t
SST
time in the table
above.
4. The System Speed Switch Time is effectively the time taken for the newly activated oscillator to start up.
5. The ROM activation time t
ACTV
should be added when calculating the total system start-up time of a wake-
up from the power down mode.