03.05 Water outlet
Steam generator outlet should be connected with water outlet by siphon (made of material resistant to high temperature)
to allow inspection and cleaning. Collecting funnel should be installed minimum of 200mm under the steam generator
drain nozzle.
03.06 Piping / empty pipes
Description
Empty pipe should be provided
Supply or connecting cable
Temperature sensor
Yes
2 x 0,5 mm
2
Wall lamp
Yes
2 x 1,5 mm
2
Control panel
Yes
4 x 0,25 mm
2
Supply air blower
Yes
3 x 1,5 mm
2
Fragrance dosing pump
Yes
2 x 1,5 mm
2
03.07 Steam pipe
Minimum cross-section tube of 35mm should be considered for steam connecting. Steam connection cables from steam
generator to steam jet should be made of copper or stainless steel with appropriate thermal insulation . The exact steam
jet position is presented in the steam cabin drawings. Steam supply cable cannot have closing valve or cut-off valve.
Furthermore, it must be protected against external impact (bending and deformation). Due to the technical requirements
for cable connections only 45 degrees elbow can be used.
03.08 Air supply blower
Air supply blower should be connected with steam jet with a pipe (HT DN 40 pipe). The attached installation instructions
for air supply blower should be followed during installation.
Summary of Contents for SteamBox 1800
Page 107: ...RU 107 04 HOESCH HOESCH HOESCH 04 01 402 8 4 334 88 1000 1 2 3 1 2...
Page 108: ...RU 108 04 02 8 50 9 5m 04 03 3 2 1 4 134627 1 134007 2 13721601 3 R1 1 4 134014 4 R1 1 4 35...
Page 111: ...RU 111 SteamBox 420 630 900 1800 08 08 01 08 02 menu exit 08 02 1 menu 0 40 20...
Page 114: ...RU 114 11 STB S 107 O FI FI...
Page 121: ...CN 121 04 HOESCH HOESCH 04 01 402 8 4 334 88 1000 1 2 3 1 2...
Page 122: ...CN 122 04 02 8 50 9 5m 04 03 3 2 1 4 134627 1 134007 2 13721601 3 R1 1 4 134014 4 R1 1 4 35...
Page 123: ...CN 123 05 27 06 R1 2 1 2 3 5 6 4 2 m 1 dm 2 5x1mm 2 3 1 2 1 8 4 CU 35mm x 1 2 5 6...
Page 125: ...CN 125 SteamBox 420 630 900 1800 08 08 01 08 02 08 02 1 0 40 20...