11 Service-Tips
Fault
Possible cause
Actions
Steam generator does not heat up
Faulty or not connected temperature
sensor
Check and replace the temperature sensor
The reason is temperature fuse
Unscrew the lid under the bottom plate, press again
temperature fuse (STB, brass)
(See
fi
gure S.23)
Water supply is blocked
Open water supply
Water supply is blocked
Clean anti-residue sieve at the solenoid valve
Anti-calc period reached
Start the anti-calc process
The whole device without voltage
The reason is FI fuse
Turn on the FI fuse once again
The reason is pre-security
Turn on the pre-security once again
There is water in the steam jet
Magnetic valve does not close properly
Check the magnetic valve
There is limescale in the device
Anti-calc process should be started