Troubleshooting
6–13
Hitachi AMS 2000 Family Storage System Service Guide
The power LED does not turn on
1. Turn the power switch ON.
2. Is the POWER LED on the base unit on?
Yes: Go to step 10.
No: Power on the host computer.
3. Is the POWER LED on the base unit on?
Yes: Go to step 10.
No: Turn the power switch OFF.
4. Check the PDB to verify that electricity is being supplied to the unit.
5. Verify that the AC cable is correctly connected to the power supply
socket and the equipment.
6. Turn the power switch ON.
7. Is the POWER LED on the base unit on?
Yes: Continue normal operation.
No: Turn the power switch OFF.
8. Call your maintenance engineer. Go to step 10.
9. Is the READY LED on?
Yes: Continue to use the equipment in its current operational state. If
the READY LED (green) blinks at a high pace, the download of the ENC
NOTE: When a base unit is used as the remote unit in a TrueCopy remote
replication/TrueCopy Extended Distance configuration, restarting the base
unit can cause the following events:
• Both paths of TrueCopy remote replication/TrueCopy Extended
Distance are blocked.
• At the time the path is blocked, Navigator 2 sends a failure notice to
the users whose email addresses are configured in the Alerts and
Events window in Navigator 2. The alert contains information regarding
the Email Alert and SNMP Agent Support features, and TRAP. Follow
the instructions in the email alert. After the remote unit has restarted,
the path blockade automatically recovers and the paths are available
for use.
• If the pair status of TrueCopy remote replication/TrueCopy Extended
Distance is PAIR or COPY, the pair status changes to PSUE.
• When the base unit must be restarted, change the pair status of
TrueCopy remote replication/TrueCopy Extended Distance to PSUS,
and then restart the unit.
NOTE: When the Power Saving storage feature is used, if you restart the
base unit while the spin-down is in progress, the spin-down may fail
because it recognizes the host immediately after the unit starts.
After the spin-down has completed, check the RAID Groups and make sure
that none of them are set to the “Normal (command monitoring)” power
saving status, then restart the unit. If the spin-down fails, start the spin-
down again.
Summary of Contents for AMS 2100
Page 8: ...viii Contents Hitachi AMS 2000 Family Storage System Service Guide ...
Page 98: ...3 6 Replaceable parts Hitachi AMS 2000 Family Storage System Service Guide ...
Page 158: ...5 10 Maintenance Hitachi AMS 2000 Family Storage System Service Guide ...
Page 182: ...7 8 Errors Hitachi AMS 2000 Family Storage System Service Guide ...
Page 191: ...Hitachi AMS 2000 Family Storage System Service Guide ...