Technical Data
180/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
CIFX 90-RE\F,
CIFX 90-RE\F\M12
Parameter
Value
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
UL Certification
The device CIFX 90-RE\F is
certified according to UL 508
UL-File-Nr. E221530
Configuration Software
Master and Slave
SYCON.net
Configuration
Configuration Software Slave
netX Configuration Tool
Table 135: Technical Data CIFX 90-RE\F, CIFX 90-RE\F\M12
10.1.6 CIFX
90-DP\F
CIFX 90E-DP\F
Parameter
Value
Name, Part No.
CIFX 90-DP\F
1290.410
Description
PC Card cifX Mini PCI PROFIBUS DP Master or Slave
and PROFIBUS MPI Device composed of:
- Basic card CIFX 90 with cable connector Fieldbus X3
and
- PROFIBUS detached network interface (AIFX-DP).
Note:
The device height and the power input of the PC Card cifX
Mini PCI CIFX 90-DP\F do not comply with the standard
specifications.
Part
Function
Communication interface with Mini PCI-Socket and
PROFIBUS interface
Communication
Controller
Type netX
100
processor
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Integrated Memory
Size of the Dual-Port Memory
64 KByte
Bus Type
Mini PCI, according to [bus spec 5], refer to section
Pin Assignment for Mini PCI Bus,
Transmission Rate
33 MHz
Data Access
DPM or DMA (Direct Memory Access)
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
PROFIBUS
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
PROFIBUS DP Master,
PROFIBUS DP Slave,
PROFIBUS MPI Device
Transmission rate
9,6 kBit/s, 19,2 kBit/s, 31,25 kBit/s, 45,45 kBit/s,
93,75 kBit/s, 187,5 kBit/s, 500 kBit/s, 1,5 MBit/s,
3 MBit/s, 6 MBit/s, 12 MBit/s
Interface Type
RS 485, refer to section
page 154.
PROFIBUS detached Network
Interface
page 229.
Important!
Operating the PC card CIFX 90-DP\F requires proper
connection of the PROFIBUS detached network interface (AIFX-
DP) to the basic card!
PROFIBUS Interface
Connector AIFX-DP
Connector Fieldbus X3
(JST 10FMN-SMT-A-TF(LF)(SN), Pitch 1,0 mm)
SYS
System Status LED
Display LED
Display
For LEDs at AIFX-DP, refer to section
page 229.