Technical Data
176/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
CIFX 80-CO
Parameter
Value
The meaning of the LED CAN depends on the loaded
firmware. Refer to chapter
, page 115.
Supply Voltage
+3.3 V dc ±5 %, refer to section
Current consumption at 3.3 V
650 mA (maximum)
Power supply
Connector
Via Compact PCI Bus
Operating temperature range*
-20 °C ... +70 °C
(
acc. to UL: 0 °C ... +70 °C
)
*Air flow during measurment
0,5 m/s
Storage temperature range
-40 °C ... +85 °C
Humidity
10 … 95% relative humidity, no condensation permitted
Environmental
Conditions
Environment
For UL compliant usage:
The device must be used in a pollution degree 2
environment.
Dimensions (L x W x H)
162,5 x 100 x 20 mm
Mounting/Installation
Compact PCI slot (3.3 V), refer to section
Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104
,
page 58.
Device
RoHS Yes
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
UL Certification
The device CIFX 80-CO is
certified according to UL 508
UL-File-Nr. E221530
Configuration Software
Master and Slave
SYCON.net
Configuration
Configuration Software Slave
netX Configuration Tool
Table 133: Technical Data CIFX 80-CO