Note
• For each access control point (door), up to four
authentication groups can be added.
• For the authentication group of which authentication type is
Local Authentication, up to 8 person/card groups can be
added to the authentication group.
• For the authentication group of which authentication type is
Local Authentication and Super Password or Local
Authentication and Remotely Open Door, up to 7 person/
card groups can be added to the authentication group.
7. Click Save.
9.4.4 Configure Custom Wiegand Rule
Based on the knowledge of uploading rule for the third party
Wiegand, you can set multiple customized Wiegand rules to
communicate between the device and the third party card
readers.
Before You Start
Wire the third party card readers to the device.
Perform this task to configure the custom Wiegand rule for the
third party card readers.
Steps
Note
• By default, the device disables the custom wiegand function. If
the device enables the custom Wiegand function, all wiegand
interfaces in the device will use the customized wiegand
protocol.
• Up to 5 custom Wiegands can be set.
• For details about the custom Wiegand, see .
1. Click Access Control Advanced Function Custom Wiegand to
enter the Custom Wiegand page.
2. Select a custom Wiegand on the left.
3. Create a Wiegand name.
Note
Up to 32 characters are allowed in the custom Wiegand name.
4. Click Select Device to select the access control device for
setting the custom wiegand.
5. Set the parity mode according to the property of the third
party card reader.
Note
• Up to 80 bits are allowed in the total length.
• The odd parity start bit, the odd parity length, the even
parity start bit and the even parity length range from 1 to 80
bit.
• The start bit of the card ID, the manufacturer code, the site
code, and the OEM should range from 1 to 80 bit.
6. Set output transformation rule.