Input Types
Operations
Fire Zone
The zone activates all the time with
sound/siren output when alarm
occurs.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Zone X fire alarm.
Gas Zone
The zone activates all the time with
sound/siren output when alarm
occurs.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Zone X gas alarm.
Medical Zone
The zone activates all the time with
beep confirmation when alarm
occurs.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Zone X medical
alarm.
Timeout Zone
The zone activates all the time. The
zone type is used to monitor and
report the "ACTIVE" status of a
zone, but it will only report and
alarm this status after the
programmed time has expired (1 to
599) seconds.
Disabled Zone
Alarms will not be activated when
the zone is triggered or tampered.
Audible Response: No system sound
(voice prompt or siren).
Virtual Zone
(Keypad/Keyfob)
The system will immediately alarm
when it detects triggering event
after system armed.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Buzzer beeps.
Tamper Alarm
The system will immediately alarm
when it detects triggering event
after system armed.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Zone X tampered.
Link
Trigger the linked device when
event occurs.
67