The zone activates all the time. It is usually used in the sites
equipped with panic button, smoke detector and glass-break
detector.
Fire Zone
The zone activates all the time with sound/siren output
when alarm occurs. It is usually used in fire hazardous areas
equipped with smoke detectors and temperature sensors.
Gas Zone
The zone activates all the time with sound/siren output
when alarm occurs. It is usually used in areas equipped with
gas detectors (e.g., the kitchen).
Medical Zone
The zone activates all the time with beep confirmation when
alarm occurs. It is usually used in places equipped with
medical emergency buttons.
Timeout Zone
The zone activates all the time. The zone type is used to
monitor and report the "ACTIVE" status of a zone, but it will
only report and alarm this status after the programmed time
has expired. (1 to 599) Seconds. It can be used in places
equipped with magnetic contacts that require access but for
only a short period (e.g., fire hydrant box's door or another
external security box door)
Disabled Zone
Alarms will not be activated when the zone is triggered or
tampered. It is usually used to disable faulty detectors .
5. Enable Stay Arming Bypass, Chime, or Silent Alarm according
to your actual needs.
Note
Some zones do not support the function. Refer to the actual
zone to set the function.
6. Enable Enroll Wireless Detector , input the serial No., and set
the linked camera No.
Note
868 Devices do not support inputting serial No.
7. Set the Disconnectin Duration, and the system determins
connection fault if the disconnected duration of the device is
longer than the configured value.
8. Click OK.
Note
After setting the zone, you can enter Status → Zone to view
the zone status.
Note
Under the System Options of the Engineer Axiom Web
platform there is an option called Early Alarm, this must be
disabled for Sweden.