Ask the network carrier to get the APN information and
input the APN information.
Data Usage Limit
You can enable the function and set the data threshold every
month. If data usage is more than the configured threshold,
an alarm will be triggered and uploaded to the alarm center
and mobile client.
Data Used This Month
The used data will be accumulated and displayed in this text
box.
4. Click Save.
Alarm Center
You can set the alarm center's parameters and all alarms will be
sent to the configured alarm center.
Steps
1. Click Communication Parameters → Alarm Receiving Center
to enter the Alarm Receiving Center page.
Figure 4-5 Alarm Receiving Center Parameters
2. Select the Alarm Receiver Center as 1 or 2 for configuration ,
and slide the slider to enable the selected alarm receiver
center.
Note
Only if the alarm receiver center 1 is enabled, you can set the
alarm receiver center 2 as the backup channel and edit the
channel parameters.
3. Select the Protocol Type as ADM-CID, EHome, SIA-DCS, *SIA-
DCS, *ADM-CID, or PSTN-CID to set uploading mode.
Note
Standard DC-09 Protocol
ADM-CID: The data presenting method of DC-09 is CID, which is
not encrypted and only for uploading alarm report.
*ADC-CID: The data presenting method of DC-09 is CID, which
is encrypted and only for uploading alarm report.
SIA-DCS: The data presenting method of DC-09 is DCS (also
called SIA protocol), which is not encrypted and only for
uploading alarm report.
*SIA-DCS: The data presenting method of DC-09 is DCS (also
called SIA protocol), which is encrypted and only for uploading
alarm report.
-
ADM-CID or SIA-DCS
17