Access level of Arming
The user in level 2 or 3 has the permission to arm or partly arm
the system.
Arming Indication
The arming/disaring indicator keeps solid blue for 5s.
Reason of Arming Failure
• Intrusion detector triggered (excepts the detector on the exit
route).
• Panic alarm device triggered.
• Tampering alarm occurred.
• Communication exception
• Mian power supply exception
• Backup battery exception
• Alarm receiving fault
• Siren fault
• Low battery of the keyfob
• Others
Arming with Fault
While the arming is stopped with fault, user in level 2 has the
permission to arm the system with fault (forced arming).
Fored arming only taks effect on the current arming operation.
The forced arming operation will be record in the event log.
5.2 Disarming
You can disarm the system with keypad, keyfob, card, client
software, or mobile client.
Disarming Indication
The arming/disarming indicator flashes 30s while the user
successfully disarm the system through the entry/exit route.
The system will report the disarming result after the operation
completed.
Entry Delay Duration
Ensure that timer is no longer than 45 seconds in order to comply
with EN50131-1.
Early Alarm
If either the intrusion or tampering alarm occurs on the enter/exit
route when the control panel is in the status of entry delay, the
control panel then enters the early alarm mode.
The early alarm duration can be set (> 30s).
The control panel will reports the alarm only if the alarm event
lasts over the duration of early alarm with the addition of entry
delay.