36
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
Figure 6.17. HEAT-ZONE-PRIMO and HEAT-OUT-PRIMO Features
HEAT-ZONE-PRIMO
Heat-Out-Primo
DAMPER
HEAT-ZONE-PRIMO Collar
Wall Switch
PowerFlow
TM
Heat
Management Toggle
LED COLOR
SWITCHES
**ATTACH WITH
ZIP TIE AT
DAMPER
HEAT-ZONE-PRIMO
HEAT-OUT-PRIMO
COLLAR
*The HEAT-OUT-PRIMO may be installed in either position shown above.
** Use included zip ties to attach the flex ducting to the damper.
*Note: Remove only one of the two middle seal plates if installing
the HEAT-OUT-PRIMO. The other plate must remain installed.
HEAT-ZONE-PRIMO Collar
*
HEAT-OUT-PRIMO Incorporated with HEAT-ZONE-PRIMO
*
WARNING! Risk of Fire!
Verify damper is opera-
tional. Overheating will occur if damper does not
open and close.
WARNING! Risk of Overheating!
Damper MUST
be installed with crimped side up. Damper will not
function properly.
* = Optional HEAT-OUT-PRIMO location
For wiring information, see Figure 8.8:
HEAT-ZONE-PRIMO incorporated with
HEAT-OUT-PRIMO.