7
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
2
2
Getting Started
A. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the outside.
No additional outside air source is required.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector,
fi
re of
fi
cials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• The vent system con
fi
guration to be used.
• Gas supply piping.
• Configuration of the required PowerFlow™ Heat
Management System: HEAT-ZONE-PRIMO and/or
HEAT-OUT-PRIMO.
C. Inspect Appliance and Components
• Carefully remove the appliance and components from
the packaging.
• The vent system components and decorative
fi
nishes
are shipped in separate packages.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
•
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and bene
fi
t.
WARNING! Risk of Fire or Explosion!
Damaged parts
could impair safe operation.
DO NOT i
nstall damaged, in-
complete or substitute components. Keep appliance dry.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure
Framing material
Pliers
Non-corrosive leak check solution
Hammer Phillips
screwdriver
Gloves Framing
square
Voltmeter
Electric drill and bits (1/4 in. magnetic)
Plumb line
Safety glasses
Level Reciprocating
saw
Manometer
Flat blade screwdriver
Suction Cups to lift glass (See Section 11)
Clamps for Granite Finish (See Section 10)
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
Caulking material (300ºF minimum continuous exposure
rating)
Hearth & Home Technologies disclaims any responsibility
for, and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modi
fi
cation of the appliance or vent system.
• Modi
fi
cation of the approved power vent system: (PVI-SLP
or PVLP-SLP)
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the media or the
fi
nishing.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a
fi
re hazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT
use this appliance if any part has been under
water. Call a quali
fi
ed service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a quali
fi
ed
service technician, service agency or your dealer.
WARNING! Risk of Fire!
PRIMO models must be
power vented using PVI-SLP or PVLP-SLP and have
a PowerFlow™ Heat Management System installed.
Failure to vent properly could cause overheating and
fi
re.
• Electrical wiring requirements.
• Framing and
fi
nishing details.
• Which required power vent system will be used: PVI-SLP
or PVLP-SLP.
WARNING! Risk of Fire!
Either the HEAT-ZONE-PRIMO
or the HEAT-OUT-PRIMO PowerFlow™ Heat Manage-
ment System must remain ON during operation of the
appliance. Overheating will occur. Appliance will shut
down.
Installation and service of this
appliance should be performed by
quali
fi
ed personnel. Hearth & Home
Technologies recommends HHT
Factory Trained or NFI certified
professionals.