35
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
HEAT-OUT-PRIMO
DAMPER***
HEAT-OUT-PRIMO
Collar
**ATTACH WITH
ZIP TIE AT
DAMPER
*The HEAT-OUT-PRIMO may be installed in either position shown above.
** Use included zip ties to attach the flex duction to the damper.
*** Verify damper is operational and no obstructions, such as screws, are present.
*Note: Remove only one of the two middle seal plates if installing
the HEAT-OUT-PRIMO. The other plate must remain installed.
*
PowerFlow
TM
Heat
Management Toggle
LED COLOR
SWITCH
DO NOT install wall switch plate and toggle
switch if only HEAT-OUT-PRIMO is installed.
Install wall switch plate and toggle switch
only when both HEAT-OUT-PRIMO and
HEAT-ZONE-PRIMO are installed
LED COLOR
SWITCH
INSTALL
Figure 6.16. HEAT-OUT-PRIMO
*
HEAT-OUT-PRIMO Feature - Configuration
WARNING! Risk of Overheating!
Damper MUST
be installed with crimped side up. Damper will not
function properly.
WARNING! Risk of Fire!
Verify damper is opera-
tional. Overheating will occur if damper does not
open and close.
* = Optional HEAT-OUT-PRIMO location