49
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
Figure 8.7 PRIMO Wiring Diagram
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.7, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™
Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the appliance.
IntelliFire
TM
Plus Ignition System Wiring
B. Wiring Requirements
RC300 4.5V DC
(AAA X 3)
2273-308
2310-211
6V TRANSFORMER
BLK
BLK
2206-299 LOCK OUT
RESET SWITCH
2196-150
PVI MODULE
2196-200 PVI-WIRE HARNESS
HEAT-ZONE-PRIMO
LED’S
2310-062
2155-204
LED SWITCH
2155-752
JUNCTION BOX
2310-211
2166-335 AUX
2155-755
(PRIMO72ST ONLY)
107-558A MALE/FEMALE
WIRE HARNESS
PVI-SLP
2155-033
JUMPER
WIRE
PVLP-SLP
2005-021
WIRE PLUG
ASSEMBLY
2310-202
THERMODISC
HEAT-OUT-PRIMO
2310-204
THERMODISC
PVI-SLP OR PVLP-SLP REQUIRED
2300-753
JUMPER WIRE
PVI-WHXX
Thick line denotes wiring
supplied by electrician.
RED
BROWN
2179-300
2159-310
2273-308
SEE THROUGH ONLY
2310-200
(TO VALVE)
ORG
GRN
GROUND
BLK