D. HEAT-OUT-PRIMO
Note:
Appliance will shut down if the HEAT-OUT-PRIMO
PowerFlow™ Heat Management System is not operating.
Contact your dealer if automatic shutdown occurs.
Figure 6.15. HEAT-OUT-PRIMO Locations
Possible Air Duct Runs/Locations
Maximum Duct Run Length: 35 FT.
Minimum Duct Run Length: 36 IN.
Clearance to
fl
exible duct = 0
Operation
The HEAT-OUT-PRIMO accessory is tested and safe when
installed in accordance with this installation manual. It is
your responsibility to read all instructions before starting
installation and to follow these instructions carefully during
installation.
Installation of this kit
MUST
be performed by a quali
fi
ed
service technician. After a quali
fi
ed service technician has
installed the appliance, including the HEAT-OUT-PRIMO
PowerFlow™ Heat Management System, follow the in-
structions supplied with the appliance manual for operation.
Contact your dealer if you have questions.
The HEAT-OUT-PRIMO feature is carefully engineered
and must be installed only as speci
fi
ed. If you modify it
or any of its components you will void the warranty, and
you may possibly cause a
fi
re hazard. Installation must be
done according to applicable local, state, provincial, and/
or national codes.
WARNING! Risk of Fire!
Either the HEAT-ZONE-PRIMO
and/or the HEAT-OUT-PRIMO Power Flow
TM
Heat Man-
agement system must remain ON during operation of the
appliance. Overheating will occur. Appliance will shut
down.
Introduction
The HEAT-OUT-PRIMO PowerFlow™ Heat Management
System is designed to remove heat from your appliance
and redirect outside the building.
Approvals
The
fl
exible ducts used with the HEAT-OUT-PRIMO fea-
ture is manufactured and marked to the requirements of
UL-181, Class I air duct.