26
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during
installation. Sheet metal edges are sharp.
A. Vent Collar Preparation
6
6
Appliance Preparation
The PRIMO is shipped standard with an attached DVP
pipe section. Do not remove. When SLP pipe will be used
for venting, the included DVP-2SLP adaptor can be used
to make the conversion from DVP pipe to SLP pipe.
1. Place the 1/8 inch thick, square pipe gasket over the
initial six inch vent section.
2. Secure square pipe gasket with four screws.
3. Attach the included DVP-2SL to the vent system with
the two screws.
Note:
The DVP-2SL may be installed at any point within
the appliance venting system.
Note:
DO NOT remove installed DVP pipe section. Use
DVP-2SL to convert for use with SLP pipe.
Figure 6.1 Vent Collar Preparation
SEAL CAP
HEAT-ZONE SEAL PLATE
DVP PIPE ATTACHED
SQUARE PIPE GASKET
HEAT-ZONE SEAL PLATE
HEAT-OUT SEAL PLATE*
HEAT-OUT SEAL PLATE*
*
Note: Remove only one of the two middle seal plates if
installing the HEAT-OUT-PRIMO. The other plate must
remain installed.
6-3/8 in.
163 mm
4-3/16 in.
106 mm
4-5/8 in.
117 mm
5-1/16 in.
128 mm
8-1/8 in.
206 mm
DVP-2SL
Adapter (Included)
4 in.
102 mm
WARNING! Risk of Fire! DO NOT
remove
PowerFlow™ Heat Management seal plate unless
a PowerFlow™ Heat Management System will be
connected at that location. Appliance will overheat.
4. Select one or both of the two required PowerFlow™
Heat Management Systems:
• Heat Zones (Quantity 2 included in kit)
(HEAT-ZONE-PRIMO)
• Heat Out
(HEAT-OUT-PRIMO)
Remove only one of the two seal plates if installing the
HEAT-OUT-PRIMO. The other HEAT-OUT-PRIMO plate
must remain in the factory-installed position.
WARNING! Risk of Overheating!
Remove only one seal
plate to install HEAT-OUT-PRIMO. Appliance will over-
heat.