©2014, Miles Industries Ltd.

Direct Vent Gas Insert

700IN (NG) & 700IP (LPG)

Installation and Owner’s Manual

Patent Pending

This manual contains instructions to install the

 

ENGINE ONLY. 

A front is

 also REQUIRED 

to 

complete this installation. A barrier screen is pro-
vided with the front. 

Refer to the manual sup-

plied with the front for installation.

— Do not store or use gasoline or other 

fl

 ammable vapors and liquids in the 

vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

 

Do not try to light any appliance.

 

Do not touch any electrical switch; do 
not use any phone in your building.

 

Leave the building immediately.

 

Immediately call your gas supplier from 
a neighbor’s phone. Follow the gas 
supplier’s instructions.

 

If you cannot reach your gas supplier, 
call the 

fi

 re department.

— Installation and service must be 

performed by a quali

fi

 ed installer, service 

agency or the gas supplier.

Ce guide est disponible en français sur demande.

This appliance is only for use with the type 
of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases, unless a certi

fi

 ed kit is used.

This appliance is a domestic room-heating 
appliance. It must not be used for any other 
purposes such as drying clothes, etc.
This appliance is suitable for installation in a 
bedroom or bed sitting room.

This appliance may be installed in an 
after-market permanently located, 
manufactured (mobile) home where not 
prohibited by local codes.

HOT GLASS

 WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN 

TO TOUCH GLASS.

DANGER

!

A barrier designed to reduce the risk of burns from the hot 
viewing glass is provided with this appliance and shall be 
installed for the protection of children and other at-risk 
individuals.

  

!

  WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage.

INSTALLER

Leave this manual 

with the appliance.

CONSUMER

Retain this manual 

for future reference.

Please read this manual 
BEFORE installing and 
operating this appliance.

Summary of Contents for Legend G3.5 700IN

Page 1: ...nible en fran ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is use...

Page 2: ...and Burner Flames 7 Glowing Ceramic Roof Panel 8 Using Handset Wall Holder 8 Replacing Batteries 8 Locating Lighting Operation and Rating Information Plate 9 Servicing Your Fireplace 9 Operating Your...

Page 3: ...E PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly...

Page 4: ...ace A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at...

Page 5: ...fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Phone Number ___________...

Page 6: ...ealers have had good results from the products listed below We cannot however guarantee the results of these products BRASSO POLISH PLUS by KELKEM COOK TOP CLEAN CREME by ELCO WHITE OFF by RUTLAND TUR...

Page 7: ...against the firebox 3 While you hold it unhook the side levers from the trim supports and hook them into the window tabs 4 Pull out the top of the window and release it to ensure the springs return i...

Page 8: ...he battery box from the receiver The appliance uses four 1 5 V AA alkaline batteries for its battery box and one 9 V alkaline battery for its handset Batteries should last one to two seasons depending...

Page 9: ...Plate The Lighting Operation and Rating information plate is located at the right of the firebox To access the plate remove the right hand side door grab the plate and take it out to read it There is...

Page 10: ...ontrol system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 35 of this manual Set scrolls through modes and settings OFF re...

Page 11: ...l flash after either Installing the battery or Simultaneously pressing the large flame and small flame buttons Press large flame button to set the hour Press small flame button to set the minute Press...

Page 12: ...the set temperature every 30 seconds NOTE 8 seconds after the fan has been set the handset will automatically go into temperature control mode The fan starts 4 minutes after the gas opens from OFF or...

Page 13: ...pm in each 24 hour cycle The Programs P1 and P2 must be set in the following order during a 24 hour cycle and The icon indicates the beginning of the period ON and the icon indicates the end of the p...

Page 14: ...eiver and the handset for a period of 6 hours the appliance goes into pilot mode No change in flame height If there is no change in flame height for a period of 6 hours the appliance goes into pilot m...

Page 15: ...GK Conversion Kit to Propane Gas 700NGK Conversion Kit to Natural Gas Hearth Gate Hearth gates such as Cardinal s VersaGates are available at retail stores carrying safety products for children Inform...

Page 16: ...ell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH 21 2 VZLWFK LQ 21 SRV...

Page 17: ...to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installations must be in accordance with the current ANSI Z223 1 and or local codes having jurisdiction Heating val...

Page 18: ...place chimney Existing hearth must be non combustible as required for existing solid fuel burning fireplaces Trim sold separately WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace...

Page 19: ...r cord outlet 6 1 8 m Fan power cord Trim sold separately Valve access panel X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combusti...

Page 20: ...le materials Material such as wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un plastered Non combustible materia...

Page 21: ...ow hits the outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum ver...

Page 22: ...Plan the routing of the gas line before proceeding Utilize the existing hole for the gas line of the factory built fireplace If the fireplace has no access hole carefully drill an access hole of 1 5 i...

Page 23: ...e installed before the appliance is fitted into the cavity Refer to instructions provided with the fan kit for its installation Remove Window The window is held in place by a spring loaded lever on ea...

Page 24: ...he back of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tap...

Page 25: ...mm flex pipe supplied with appliance Shut off valve supplied with appliance 1 2 NPT female The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve duri...

Page 26: ...e appli ance case NOTE the flex connector minimum bend radius must be no smaller than the size of a golf ball approx 1 3 4 or 44 mm as indicated Alternate Inlet Connection When the fireplace opening w...

Page 27: ...anel against the back of the firebox on the ledge at bottom 5 Rotate the anchor up and out of the way and slide the left hand side panel against the firebox side Rotate the anchor back down to hold th...

Page 28: ...ogs very carefully to avoid damaging the fragile material Install the logs as shown below Please note that the position of the Logs is critical to insure proper performance of the appliance 11 With lo...

Page 29: ...end rests on the glass and should be rotated forward against the cast grate allowing flames to come up behind the left log 4 Place the right front log with its left end flat on the glass The notch in...

Page 30: ...s wider end on the front right log s peg and rest its narrow end in the notch on the rear log 7 If desired add loose embers on top of the front bricks between the legs of the grate in the shaded space...

Page 31: ...firebox on top of the burner The metal tabs at the bottom of the platform slide into the slots in front of the burner 2 3 Insert the ceramic rock base in the platform behind the burner Ensure that the...

Page 32: ...1 9 7 17 18 13 6 8 10 8 Identify the rocks 7 9 11 and 14 These rocks have one hole underneath and fit on the peg of the rocks 6 8 10 and 13 respectively Install these rocks positioning them so that th...

Page 33: ...as they do not block the pilot flame or the burner flame 12 Optional As well you can add the front bricks if desired sliding them under the platform front edge Install Side Shrouds The side shrouds a...

Page 34: ...ook them into the window brackets on each side 4 Pull out the top of the window and release it to ensure the springs return it 5 Apply light hand pressure against the window frame sides to bed in the...

Page 35: ...ry box upside on the left of the firebox Battery box connection Reset button Battery box Remove cover Connect battery box to wire 5 With a sharp object press and hold the receiver s reset button until...

Page 36: ...logs and window installed Increasing aeration open will cause the flames to appear more transparent and blue showing more ceramic log glow Decreasing aeration close will cause the flames to appear mor...

Page 37: ...ll find a convenient location and use the hardware provided with the kit See the diagram below for required hardware and configurations Note that the holder can be installed at the base of a light swi...

Page 38: ...Red Yellow Wiring Diagram Remote Battery Box Optional Fan Control Module 4 AA Batteries GV60 MAX Wiring Diagram Optional Wall Switch Kit 1265WSK Connector 38 QUALIFIED INSTALLER...

Page 39: ...ial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and othe...

Page 40: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass log...

Page 41: ...002700 32 Thermocurrent interruptor 4001037 33a GV60 Valve assembly NG 4003162 33b GV60 Valve assembly LPG 4003163 34 34 flex pipe with shut off valve 4002475 Code Description Part Number 34a Inlet el...

Page 42: ...83 Rear panel a Ledgestone 4003192 b Enamel black 4003201EB c Ceramic fluted black 4003210 d Valor red brick 4003219 84 Left side panel a Ledgestone 4003190 b Enamel black 4003199EB c Ceramic fluted...

Page 43: ...55 56 57 79 80 80a 81 82 83 84 85 86 87 16 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 41 1 2 3 7 8 9 10 11 12 13 14 NG LPG 17 23a 24 25 26 27 31 34 37 38 35 36 25a 15 48 32 34a 33...

Page 44: ...44...

Page 45: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Page 46: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...