16.2 Temperature Controller/Servo/Inverter Connection
16-31
16.2.6 F-MPC04P (Loader)
Communication Setting
Editor
Communication setting
(Underlined setting: default)
*1 To use port No. 32 to 99, use the station number table.
Power Monitor Unit
Be sure to match the settings to those made under [Communication Setting] of the editor.
Station number setting
Communication setting
The communication parameter can be set using keys attached to the front of the power monitor unit.
(Underlined setting: default)
* The communication parameter (stop bit) is fixed to 1 bit.
Available Device Memory
The available setting range of device memory varies depending on the model. Be sure to set within the range available for the
model to be used. Use [TYPE] when assigning indirect device memory for macro programs.
Item
Setting
Remarks
Connection Mode
1
:
1 / 1
:
n / Multi-link2 /
Multi-link2 (Ethernet) /
1
:
n Multi-link2 (Ethernet)
Signal Level
RS-422/485
Baud Rate
4800 / 9600 / 19200 bps
Data Length
7 / 8 bits
Stop Bit
1 bit
Do not change the default setting because the setting on the
power monitor unit cannot be changed.
Parity
None / Odd / Even
Target Port No.
1 to 99
*1
Station
Setting
Example
Remarks
01 to 99 [DEC] (default: 0)
1
Circuit No.
Setting Code
Item
Setting
Example
C
L1-
Baud rate
00: 4800 bps
01: 9600 bps
02: 19200 bps
02
L2-
Parity
00: None
01: Even
02: Odd
02
L3-
Data length
00: 7 bits
01: 8 bits
00
ADDRESS SW
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
Device Memory
TYPE
Remarks
---
00H
Double-word
Summary of Contents for Monitouch V9 Series
Page 76: ...1 64 1 Overview Please use this page freely...
Page 77: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 119: ...2 42 2 ALLEN BRADLEY Please use this page freely...
Page 120: ...3 1 PLC Connection 3 Automationdirect...
Page 131: ...4 1 PLC Connection 4 2 Temperature Controller Servo Inverter Connection 4 Azbil...
Page 164: ...5 1 PLC Connection 5 Baumuller...
Page 169: ...6 1 PLC Connection 6 BECKHOFF...
Page 174: ...7 1 Temperature Controller Servo Inverter Connection 7 CHINO...
Page 193: ...8 1 PLC Connection 8 CIMON...
Page 206: ...9 1 PLC Connection 9 DELTA...
Page 211: ...10 1 Temperature Controller Servo Inverter Connection 10 DELTA TAU DATA SYSTEMS...
Page 222: ...11 EATON Cutler Hammer 11 1 PLC Connection...
Page 227: ...12 1 PLC Connection 12 EMERSON...
Page 232: ...13 FANUC 13 1 PLC Connection...
Page 238: ...13 6 13 FANUC Please use this page freely...
Page 239: ...14 Fatek Automation 14 1 PLC Connection...
Page 245: ...14 6 14 Fatek Automation Please use this page freely...
Page 246: ...15 1 PLC Connection 15 FUFENG...
Page 252: ...15 6 15 FUFENG Please use this page freely...
Page 253: ...16 Fuji Electric 16 1 PLC Connection 16 2 Temperature Controller Servo Inverter Connection...
Page 357: ...16 104 16 Fuji Electric Please use this page freely...
Page 358: ...17 1 Temperature Controller Servo Inverter 17 Gammaflux...
Page 364: ...17 6 17 Gammaflux Please use this page freely...
Page 365: ...18 GE Fanuc 18 1 PLC Connection...
Page 380: ...19 1 PLC Connection 19 Hitachi...
Page 394: ...19 14 19 Hitachi Please use this page freely...
Page 423: ...20 28 20 Hitachi Industrial Equipment Systems Please use this page freely...