1-38
1.
Overview
* For settings other than the above, see “1.4 Hardware Settings” (page 1-43).
IP Address Setting of the V9 Series
An IP address must be set for the V9 to connect to devices via Ethernet. Set the IP address either on the V9 unit or for the
screen program using the V-SFT editor.
Setting Using the V-SFT Editor
Set the IP address at [System Setting]
[Hardware Setting]
[Local Port IP Address].
Local port IP address setting
Target Settings
Connect To
These settings are valid when [1 : 1] is selected for [Connection Mode].
Select the IP address of the PLC registered in the PLC table. 1 : 1 communications are
executed with the PLC selected here.
PLC Table
Click [Setting] to display the [PLC Table] window.
Set the IP address, port number and KeepAlive function (under development) of the
PLC.
Item
Contents
Item
Contents
Select IP Address from
Network Table
This is valid when the IP address of the V9 has been registered in the network table.
Select a network table number from 0 to 255 to set the IP address.
* For more information on the network table, refer to “ Network table” (page 1-50).
IP Address
*1
Set the IP address for the V9.
Default Gateway
*1
Set the default gateway.
Subnet Mask
*1
Set the subnet mask.
When this box is not checked, the subnet mask is automatically assigned based on the byte at the extreme
left of the IP address.
Example:
When IP address is “172.16.200.185”, “255.255.0.0” is set.
When IP address is “192.168.1.185”, “255.255.255.0” is set.
Port No.
*1
Set a port number from 1024 to 65535.
(Excluding 8001 and 8020)
Summary of Contents for Monitouch V9 Series
Page 76: ...1 64 1 Overview Please use this page freely...
Page 77: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 119: ...2 42 2 ALLEN BRADLEY Please use this page freely...
Page 120: ...3 1 PLC Connection 3 Automationdirect...
Page 131: ...4 1 PLC Connection 4 2 Temperature Controller Servo Inverter Connection 4 Azbil...
Page 164: ...5 1 PLC Connection 5 Baumuller...
Page 169: ...6 1 PLC Connection 6 BECKHOFF...
Page 174: ...7 1 Temperature Controller Servo Inverter Connection 7 CHINO...
Page 193: ...8 1 PLC Connection 8 CIMON...
Page 206: ...9 1 PLC Connection 9 DELTA...
Page 211: ...10 1 Temperature Controller Servo Inverter Connection 10 DELTA TAU DATA SYSTEMS...
Page 222: ...11 EATON Cutler Hammer 11 1 PLC Connection...
Page 227: ...12 1 PLC Connection 12 EMERSON...
Page 232: ...13 FANUC 13 1 PLC Connection...
Page 238: ...13 6 13 FANUC Please use this page freely...
Page 239: ...14 Fatek Automation 14 1 PLC Connection...
Page 245: ...14 6 14 Fatek Automation Please use this page freely...
Page 246: ...15 1 PLC Connection 15 FUFENG...
Page 252: ...15 6 15 FUFENG Please use this page freely...
Page 253: ...16 Fuji Electric 16 1 PLC Connection 16 2 Temperature Controller Servo Inverter Connection...
Page 357: ...16 104 16 Fuji Electric Please use this page freely...
Page 358: ...17 1 Temperature Controller Servo Inverter 17 Gammaflux...
Page 364: ...17 6 17 Gammaflux Please use this page freely...
Page 365: ...18 GE Fanuc 18 1 PLC Connection...
Page 380: ...19 1 PLC Connection 19 Hitachi...
Page 394: ...19 14 19 Hitachi Please use this page freely...
Page 423: ...20 28 20 Hitachi Industrial Equipment Systems Please use this page freely...