4.1 PLC Connection
4-3
MX200
Make the following settings on the front panel. For more information, refer to the PLC manual issued by the manufacturer.
LOAD connector
(Underlined setting: default)
ASCII connector
(Underlined setting: default)
Station number
Make the following setting on the front panel.
(Underlined setting: default)
Calendar
This model is equipped with a calendar function; however, the calendar data cannot be written from the V series. Thus, time
correction must be performed on the PLC side.
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
Communication Setup Mode
Setting
Remarks
LOAD
connector
setting
Item 0: Address setting
1 to 63 (DEC): 1 to 63
7F(HEX): 127
Settings can also be made in the
PLC application software.
For more information, refer to
the PLC manual issued by the
manufacturer.
Item 1: Baud rate
48: 4800 bps
96: 9600 bps
192: 19200 bps
Item 2: Communication
mode
8E1: data length 8 bits, even parity, 1 stop bit
8n2: data length 8 bits, without parity, 2 stop bits
Communication Setup Mode
Setting
Remarks
ASCII
connector
setting
Item 0: Baud rate
48: 4800 bps
96: 9600 bps
192: 19200 bps
Settings can also be made in the
PLC application software.
For more information, refer to the
PLC manual issued by the
manufacturer.
Item 1: Data length
7b: 7 bits
8b: 8 bits
Item 2: Parity bit
EP: Even
oP: Odd
nP: None
Item 3: Stop bit
1S: 1 bit
2S: 2 bits
Item 4: Connector usage
Ldr: LOAD connector
Item 5: Connecting
device selection
CPL: Yamatake communication support device
Item 7: RTS control
non: No RTS control
Item 8: Signal level
selection
232: RS-232C
MX Address Display/Setting Mode
Setting
Remarks
Addr
1 to 63
Device Memory
TYPE
Remarks
R
(data register)
00H
R910, 929, 930, 956 to 987, 994 to 997: Read only
M
(auxiliary relay)
01H
M920 to 940, 970 to 990: Read only
L
(latch relay)
02H
X
(input relay)
03H
Y
(output relay)
04H
TP
(timer/current value)
05H
Data format: BCD
TS
(timer/set value)
06H
Data format: BCD
CP
(counter/current value)
07H
Data format: BCD
CS
(counter/set value)
08H
Data format: BCD
T
(timer/contact)
09H
C
(counter/contact)
0AH
P
(link register)
0BH
Summary of Contents for Monitouch V9 Series
Page 76: ...1 64 1 Overview Please use this page freely...
Page 77: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 119: ...2 42 2 ALLEN BRADLEY Please use this page freely...
Page 120: ...3 1 PLC Connection 3 Automationdirect...
Page 131: ...4 1 PLC Connection 4 2 Temperature Controller Servo Inverter Connection 4 Azbil...
Page 164: ...5 1 PLC Connection 5 Baumuller...
Page 169: ...6 1 PLC Connection 6 BECKHOFF...
Page 174: ...7 1 Temperature Controller Servo Inverter Connection 7 CHINO...
Page 193: ...8 1 PLC Connection 8 CIMON...
Page 206: ...9 1 PLC Connection 9 DELTA...
Page 211: ...10 1 Temperature Controller Servo Inverter Connection 10 DELTA TAU DATA SYSTEMS...
Page 222: ...11 EATON Cutler Hammer 11 1 PLC Connection...
Page 227: ...12 1 PLC Connection 12 EMERSON...
Page 232: ...13 FANUC 13 1 PLC Connection...
Page 238: ...13 6 13 FANUC Please use this page freely...
Page 239: ...14 Fatek Automation 14 1 PLC Connection...
Page 245: ...14 6 14 Fatek Automation Please use this page freely...
Page 246: ...15 1 PLC Connection 15 FUFENG...
Page 252: ...15 6 15 FUFENG Please use this page freely...
Page 253: ...16 Fuji Electric 16 1 PLC Connection 16 2 Temperature Controller Servo Inverter Connection...
Page 357: ...16 104 16 Fuji Electric Please use this page freely...
Page 358: ...17 1 Temperature Controller Servo Inverter 17 Gammaflux...
Page 364: ...17 6 17 Gammaflux Please use this page freely...
Page 365: ...18 GE Fanuc 18 1 PLC Connection...
Page 380: ...19 1 PLC Connection 19 Hitachi...
Page 394: ...19 14 19 Hitachi Please use this page freely...
Page 423: ...20 28 20 Hitachi Industrial Equipment Systems Please use this page freely...