16-28
16. Fuji Electric
16.2.4 PXH (MODBUS RTU)
Communication Setting
Editor
Communication setting
(Underlined setting: default)
Temperature Controller
The communication parameter can be set using keys attached to the front of the temperature controller.
Be sure to match the settings to those made under [Communication Setting] of the editor.
(Underlined setting: default)
* The communication function of the temperature controller can be selected at the time of purchase. Select a model on which RS-485
(Modbus) communication is available.
* The following communication parameters are fixed; data length: 8 bits and stop bit: 1 bit.
Available Device Memory
The available setting range of device memory varies depending on the model. Be sure to set within the range available for the
model to be used. Use [TYPE] when assigning indirect device memory for macro programs.
Item
Setting
Remarks
Connection Mode
1
:
1 / 1
:
n / Multi-link2 /
Multi-link2 (Ethernet) /
1
:
n Multi-link2 (Ethernet)
Signal Level
RS-422/485
Do not change the default settings of the signal level, data
length and stop bit because these settings on the temperature
controller cannot be changed.
Baud Rate
9600 / 19200 / 38400 bps
Data Length
8 bits
Stop Bit
1 bit
Parity
None / Even / Odd
Target Port No.
1 to 31
Channel
Parameter Display
Item
Setting
Example
Communication (Ch B)
STn4
RS-485 station No.
1 to 31
1
SPd4
RS-485 baud rate
96: 9600 bps
192: 19200 bps
384: 38400 bps
384
biT4
RS-485 bit format
8n: Data length 8 bits, without parity
8o: Data length 8 bits, odd parity
8E: Data length 8 bits, even parity
8o
Device Memory
TYPE
Remarks
4
(holding register)
02H
3
(input register)
03H
Summary of Contents for Monitouch V9 Series
Page 76: ...1 64 1 Overview Please use this page freely...
Page 77: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 119: ...2 42 2 ALLEN BRADLEY Please use this page freely...
Page 120: ...3 1 PLC Connection 3 Automationdirect...
Page 131: ...4 1 PLC Connection 4 2 Temperature Controller Servo Inverter Connection 4 Azbil...
Page 164: ...5 1 PLC Connection 5 Baumuller...
Page 169: ...6 1 PLC Connection 6 BECKHOFF...
Page 174: ...7 1 Temperature Controller Servo Inverter Connection 7 CHINO...
Page 193: ...8 1 PLC Connection 8 CIMON...
Page 206: ...9 1 PLC Connection 9 DELTA...
Page 211: ...10 1 Temperature Controller Servo Inverter Connection 10 DELTA TAU DATA SYSTEMS...
Page 222: ...11 EATON Cutler Hammer 11 1 PLC Connection...
Page 227: ...12 1 PLC Connection 12 EMERSON...
Page 232: ...13 FANUC 13 1 PLC Connection...
Page 238: ...13 6 13 FANUC Please use this page freely...
Page 239: ...14 Fatek Automation 14 1 PLC Connection...
Page 245: ...14 6 14 Fatek Automation Please use this page freely...
Page 246: ...15 1 PLC Connection 15 FUFENG...
Page 252: ...15 6 15 FUFENG Please use this page freely...
Page 253: ...16 Fuji Electric 16 1 PLC Connection 16 2 Temperature Controller Servo Inverter Connection...
Page 357: ...16 104 16 Fuji Electric Please use this page freely...
Page 358: ...17 1 Temperature Controller Servo Inverter 17 Gammaflux...
Page 364: ...17 6 17 Gammaflux Please use this page freely...
Page 365: ...18 GE Fanuc 18 1 PLC Connection...
Page 380: ...19 1 PLC Connection 19 Hitachi...
Page 394: ...19 14 19 Hitachi Please use this page freely...
Page 423: ...20 28 20 Hitachi Industrial Equipment Systems Please use this page freely...