1.3 Connection Methods
1-13
RS-485 (2-wire system) connection
Use Hakko Electronics’ cable “V6-TMP” (3, 5, 10 m) as a communication cable.
The maximum length of wiring is 500 m.
* The maximum length varies depending on the connected device. Check the specifications for each device.
If the PLC has a signal ground (SG) terminal, connect it.
The DIP switch on the back of the V9 unit is used to set the terminating resistance. For more information, see “1.2.6 DIP
Switch (DIPSW) Settings” (page 1-7).
Connect a shielded cable to either the V9 series or the connected device. Connect the cable to the FG terminal on the
backside of MONITOUCH.
If noise disturbs communications, connect a shielded cable to both the V9 series and the connected device.
CAUTION
The MJ1 and MJ2 are not usable for connection via RS-422 (4-wire system). Use the CN1 port
instead or a commercially available RS-232C-to-RS-422 converter.
SG
RJ - 45
MJ1/2
Name
No.
1
2
5
+RD/+SD
-RD/-SD
SG
FG
1 2 3 4 5 6 7 8
Shielded
RS-485 port of the
connected device
Send/receive
data (+)
Send/receive
data (
)
SG
FG
RJ - 45
MJ1/2
Name
No.
1
2
5
+RD/+SD
-RD/-SD
SG
FG
1 2 3 4 5 6 7 8
Shielded
RS-485 port of the
connected device
Send/receive
data (+)
Send/receive
data (-)
Summary of Contents for Monitouch V9 Series
Page 76: ...1 64 1 Overview Please use this page freely...
Page 77: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 119: ...2 42 2 ALLEN BRADLEY Please use this page freely...
Page 120: ...3 1 PLC Connection 3 Automationdirect...
Page 131: ...4 1 PLC Connection 4 2 Temperature Controller Servo Inverter Connection 4 Azbil...
Page 164: ...5 1 PLC Connection 5 Baumuller...
Page 169: ...6 1 PLC Connection 6 BECKHOFF...
Page 174: ...7 1 Temperature Controller Servo Inverter Connection 7 CHINO...
Page 193: ...8 1 PLC Connection 8 CIMON...
Page 206: ...9 1 PLC Connection 9 DELTA...
Page 211: ...10 1 Temperature Controller Servo Inverter Connection 10 DELTA TAU DATA SYSTEMS...
Page 222: ...11 EATON Cutler Hammer 11 1 PLC Connection...
Page 227: ...12 1 PLC Connection 12 EMERSON...
Page 232: ...13 FANUC 13 1 PLC Connection...
Page 238: ...13 6 13 FANUC Please use this page freely...
Page 239: ...14 Fatek Automation 14 1 PLC Connection...
Page 245: ...14 6 14 Fatek Automation Please use this page freely...
Page 246: ...15 1 PLC Connection 15 FUFENG...
Page 252: ...15 6 15 FUFENG Please use this page freely...
Page 253: ...16 Fuji Electric 16 1 PLC Connection 16 2 Temperature Controller Servo Inverter Connection...
Page 357: ...16 104 16 Fuji Electric Please use this page freely...
Page 358: ...17 1 Temperature Controller Servo Inverter 17 Gammaflux...
Page 364: ...17 6 17 Gammaflux Please use this page freely...
Page 365: ...18 GE Fanuc 18 1 PLC Connection...
Page 380: ...19 1 PLC Connection 19 Hitachi...
Page 394: ...19 14 19 Hitachi Please use this page freely...
Page 423: ...20 28 20 Hitachi Industrial Equipment Systems Please use this page freely...