16-8
16. Fuji Electric
NW0LA-RS2, NW0LA-RS4 (parameter setting)
On the PLC loader, set parameters for general communications.
Be sure to match the settings to those made under [Communication Setting] of the editor.
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
Item
Setting
Remarks
Mode
General (Command asyn)
These settings can also be specified for
the parameter area.
For more information, refer to the
MICREX-SX SPB Series User’s Manual
<Communication Adapter> (FEH405).
Station No.
RS-232C: 0, RS-485: 0 to 31
Initialize method
Set parameters
Baud rate
4800 / 9600 / 19200 / 38400
Parity
Odd / Even / None
Data bits
8 / 7
Stop bits
1 / 2
Notes on use of 2-wire connection with NW0LA-RS4
The settings show above are not enough to establish a 2-wire connection with NW0LA-RS4.
To establish a connection, select [Initial file transfer] for [Initial Setting Mode] on the PLC loader, and select 2-wire
connection for [485 mode] in the initial setting file.
For more information, refer to the MICREX-SX SPB Series User’s Manual <Communication Adapter> (FEH405).
Standard Device Memory
TYPE
Remarks
D
(data register)
00H
W
(link register)
01H
M
(internal relay)
02H
WM as word device
L
(latch relay)
03H
WL as word device
X
(input relay)
04H
WX as word device
Y
(output relay)
05H
WY as word device
R
(file register)
06H
TN
(timer/current value)
07H
CN
(counter/current value)
08H
T
(timer/contact)
09H
C
(counter/contact)
0AH
WS
(step relay)
0BH
Summary of Contents for Monitouch V9 Series
Page 76: ...1 64 1 Overview Please use this page freely...
Page 77: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 119: ...2 42 2 ALLEN BRADLEY Please use this page freely...
Page 120: ...3 1 PLC Connection 3 Automationdirect...
Page 131: ...4 1 PLC Connection 4 2 Temperature Controller Servo Inverter Connection 4 Azbil...
Page 164: ...5 1 PLC Connection 5 Baumuller...
Page 169: ...6 1 PLC Connection 6 BECKHOFF...
Page 174: ...7 1 Temperature Controller Servo Inverter Connection 7 CHINO...
Page 193: ...8 1 PLC Connection 8 CIMON...
Page 206: ...9 1 PLC Connection 9 DELTA...
Page 211: ...10 1 Temperature Controller Servo Inverter Connection 10 DELTA TAU DATA SYSTEMS...
Page 222: ...11 EATON Cutler Hammer 11 1 PLC Connection...
Page 227: ...12 1 PLC Connection 12 EMERSON...
Page 232: ...13 FANUC 13 1 PLC Connection...
Page 238: ...13 6 13 FANUC Please use this page freely...
Page 239: ...14 Fatek Automation 14 1 PLC Connection...
Page 245: ...14 6 14 Fatek Automation Please use this page freely...
Page 246: ...15 1 PLC Connection 15 FUFENG...
Page 252: ...15 6 15 FUFENG Please use this page freely...
Page 253: ...16 Fuji Electric 16 1 PLC Connection 16 2 Temperature Controller Servo Inverter Connection...
Page 357: ...16 104 16 Fuji Electric Please use this page freely...
Page 358: ...17 1 Temperature Controller Servo Inverter 17 Gammaflux...
Page 364: ...17 6 17 Gammaflux Please use this page freely...
Page 365: ...18 GE Fanuc 18 1 PLC Connection...
Page 380: ...19 1 PLC Connection 19 Hitachi...
Page 394: ...19 14 19 Hitachi Please use this page freely...
Page 423: ...20 28 20 Hitachi Industrial Equipment Systems Please use this page freely...