16-66
16. Fuji Electric
16.2.21HFR-C11K
Communication Setting
Editor
Communication setting
(Underlined setting: default)
IH Inverter
Be sure to match the settings to those made under [Communication Setting] of the editor. (Underlined setting: default)
SW3 setting (station address / terminating resistance)
*1 For connection to a V9, be sure to set the station address other than 0.
Communication setting
Set communication parameters.
Be sure to match the settings to those made under [Communication Setting] of the editor.
(Underlined setting: default)
* RS-485 communication is available when the communication is enabled by digital input.
Example:
To make the communication enabled when digital input terminal X1 is turned ON;
Set “11 (RS485 communication selection (RS))” for function code i01 and turn on the digital input terminal X1 externally.
Terminals from X2 to X5 can also be used. Set the function code corresponding to the digital input terminal to use.
Item
Setting
Remarks
Connection Mode
1
:
1 / 1
:
n / Multi-link2 /
Multi-link2 (Ethernet) /
1
:
n Multi-link2 (Ethernet)
Signal Level
RS-422/485
Baud Rate
4800 / 9600 / 19200 bps
Data Length
7 / 8 bits
Stop Bit
1 / 2 bits
Parity
None / Odd / Even
Target Port No.
1 to 31
Switch
Contents
Example:
Station Address: 1
Terminating Resistance: None
1
Station
Address
*1
2
3
4
5
6
Terminating
Resistance
Function Code
Item
Setting
Example
r 04
Baud rate
2: 4800 bps
3: 9600 bps
4: 19200 bps
3
r 05
Data length
0: 8 bit
1: 7 bits
1
r 06
Parity bit
0: None
1: Even
2: Odd
1
r 07
Stop bit
0: 2 bit
1: 1 bits
1
r 10
Communication protocol
*
0: FGI-bus
1: C9K mode
0
1
2
3
4
5
0
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
:
:
:
:
:
:
28
OFF
OFF
ON
ON
ON
29
ON
OFF
ON
ON
ON
30
OFF
ON
ON
ON
ON
31
ON
ON
ON
ON
ON
Address
Switch
ON
OFF
124
8
1
6
ON
12
345
6
T
e
rminating
Resistance
Contents
OFF
ON
Terminating resistance
None
Provided
Summary of Contents for Monitouch V9 Series
Page 76: ...1 64 1 Overview Please use this page freely...
Page 77: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 119: ...2 42 2 ALLEN BRADLEY Please use this page freely...
Page 120: ...3 1 PLC Connection 3 Automationdirect...
Page 131: ...4 1 PLC Connection 4 2 Temperature Controller Servo Inverter Connection 4 Azbil...
Page 164: ...5 1 PLC Connection 5 Baumuller...
Page 169: ...6 1 PLC Connection 6 BECKHOFF...
Page 174: ...7 1 Temperature Controller Servo Inverter Connection 7 CHINO...
Page 193: ...8 1 PLC Connection 8 CIMON...
Page 206: ...9 1 PLC Connection 9 DELTA...
Page 211: ...10 1 Temperature Controller Servo Inverter Connection 10 DELTA TAU DATA SYSTEMS...
Page 222: ...11 EATON Cutler Hammer 11 1 PLC Connection...
Page 227: ...12 1 PLC Connection 12 EMERSON...
Page 232: ...13 FANUC 13 1 PLC Connection...
Page 238: ...13 6 13 FANUC Please use this page freely...
Page 239: ...14 Fatek Automation 14 1 PLC Connection...
Page 245: ...14 6 14 Fatek Automation Please use this page freely...
Page 246: ...15 1 PLC Connection 15 FUFENG...
Page 252: ...15 6 15 FUFENG Please use this page freely...
Page 253: ...16 Fuji Electric 16 1 PLC Connection 16 2 Temperature Controller Servo Inverter Connection...
Page 357: ...16 104 16 Fuji Electric Please use this page freely...
Page 358: ...17 1 Temperature Controller Servo Inverter 17 Gammaflux...
Page 364: ...17 6 17 Gammaflux Please use this page freely...
Page 365: ...18 GE Fanuc 18 1 PLC Connection...
Page 380: ...19 1 PLC Connection 19 Hitachi...
Page 394: ...19 14 19 Hitachi Please use this page freely...
Page 423: ...20 28 20 Hitachi Industrial Equipment Systems Please use this page freely...