16.2 Temperature Controller/Servo/Inverter Connection
16-91
16.2.33WSZ Series
Communication Setting
Editor
Communication setting
(Underlined setting: default)
WSZ Series
Make settings for the controller by using the software “WinProladder”. For more information, refer to the instruction manual
of the controller issued by the manufacturer.
Station Number
(Underlined setting: default)
PORT 0
Comm. Parameters Setting - Port 0
(Underlined setting: default)
* The following settings are fixed; data length: 7, stop bit: 1, parity: even, and protocol: Fatek Communication protocol.
WSZ-CB25 (PORT 1 / PORT 2)
Comm. Parameters Setting - Port 1 / Port 2
(Underlined setting: default)
DIPSW
Item
Setting
Remarks
Connection Mode
1 : 1 / 1 : n / Multi-link2 /
Multi-link2 (Ethernet) /
1 : n Multi-link2 (Ethernet)
Signal Level
RS-232C / RS-422/485
Baud Rate
4800 / 9600 / 19200 / 38400 / 57600 /
76800 / 115k bps
Data Length
7 / 8 bits
Stop Bit
1 / 2 bits
Parity
None / Even / Odd
Target Port No.
1 to 254
Setting Items
Setting
Remarks
Station Number
1 to 254
Setting Items
Setting
Remarks
Baud Rate
9600 / 19200 / 38400 / 57600 / 115200
The baud rate can also be set by
specifying a value for the designated
address.
For more information, refer to the
instruction manual of the controller issued
by the manufacturer.
Setting Items
Setting
Remarks
Baud Rate
4800 / 9600 / 19200 / 38400 / 57600 / 76800 / 115200
The baud rate can also be set by
specifying a value for the designated
address.
For more information, refer to the
instruction manual of the controller issued
by the manufacturer.
Parity
None / Even / Odd
Data Bit
7 / 8
Stop Bit
1 / 2
Protocol
Fatek Communication protocol
Setting Items
Setting
Remarks
Terminating resistance
ON: With terminating resistance
OFF: Without terminating resistance
This setting must be the same for both
switches.
ON
T
N
Summary of Contents for Monitouch V9 Series
Page 76: ...1 64 1 Overview Please use this page freely...
Page 77: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 119: ...2 42 2 ALLEN BRADLEY Please use this page freely...
Page 120: ...3 1 PLC Connection 3 Automationdirect...
Page 131: ...4 1 PLC Connection 4 2 Temperature Controller Servo Inverter Connection 4 Azbil...
Page 164: ...5 1 PLC Connection 5 Baumuller...
Page 169: ...6 1 PLC Connection 6 BECKHOFF...
Page 174: ...7 1 Temperature Controller Servo Inverter Connection 7 CHINO...
Page 193: ...8 1 PLC Connection 8 CIMON...
Page 206: ...9 1 PLC Connection 9 DELTA...
Page 211: ...10 1 Temperature Controller Servo Inverter Connection 10 DELTA TAU DATA SYSTEMS...
Page 222: ...11 EATON Cutler Hammer 11 1 PLC Connection...
Page 227: ...12 1 PLC Connection 12 EMERSON...
Page 232: ...13 FANUC 13 1 PLC Connection...
Page 238: ...13 6 13 FANUC Please use this page freely...
Page 239: ...14 Fatek Automation 14 1 PLC Connection...
Page 245: ...14 6 14 Fatek Automation Please use this page freely...
Page 246: ...15 1 PLC Connection 15 FUFENG...
Page 252: ...15 6 15 FUFENG Please use this page freely...
Page 253: ...16 Fuji Electric 16 1 PLC Connection 16 2 Temperature Controller Servo Inverter Connection...
Page 357: ...16 104 16 Fuji Electric Please use this page freely...
Page 358: ...17 1 Temperature Controller Servo Inverter 17 Gammaflux...
Page 364: ...17 6 17 Gammaflux Please use this page freely...
Page 365: ...18 GE Fanuc 18 1 PLC Connection...
Page 380: ...19 1 PLC Connection 19 Hitachi...
Page 394: ...19 14 19 Hitachi Please use this page freely...
Page 423: ...20 28 20 Hitachi Industrial Equipment Systems Please use this page freely...