403
REQUIRED REAGENTS
Cat. No.
High Range Silica Reagent Set, 25-mL sample (100 tests) .........................................22443-00
Includes: (1) 1042-99, (1) 14548-99, (1) 1041-99
Quantity Required
Description
Per Test
Units
Cat. No.
Acid Reagent Powder Pillows for High Range Silica...1 .....................100/pkg ............1042-99
Citric Acid Powder Pillows...........................................1 .....................100/pkg ..........14548-99
Molybdate Reagent Powder Pillows for HR Silica.......1 .....................100/pkg ............1041-99
Water, deionized ....................................................... 30 mL ........................ 4 L ..............272-56
REQUIRED APPARATUS
Sample 10-20-15 mL, w/ cap ........................................2 .........................6/pkg ..........24019-06
OPTIONAL REAGENTS
Silica Standard Solution, 10 mg/L ........................................................ 500 mL ............1403-49
Silica Standard Solution, 25 mg/L ........................................................ 236 mL ..........21225-31
Silica Standard Solution, 50 mg/L ........................................................ 200 mL ............1117-29
Silica Standard Solution, 1000 mg/L .................................................... 500 mL ..............194-49
Sodium Bicarbonate, ACS ........................................................................ 454 g ..............776-01
Sulfuric Acid Standard Solution, 1.000 N................................... 100 mL MDB ............1270-32
OPTIONAL APPARATUS
Flask, volumetric, 250 mL, Class A............................................................each ..........14574-46
Pipet, TenSette, 0.1 to 1.0 mL .....................................................................each ..........19700-01
Pipet Tips, for 19700-01 Pipet ................................................................50/pkg ..........21856-96
Pipet, volumetric, Class A, 100 mL ............................................................each ..........14515-42
Pipet Filler, safety bulb ...............................................................................each ..........14651-00
Standard Methods for the Examination of Water and Wastewater
.............each ..........22708-00
Thermometer, -20 to 110 °C, Non-Mercury................................................each ..........26357-02
For Technical Assistance, Price and Ordering
In the U.S.A.—Call 800-227-4224
Outside the U.S.A.—Contact the Hach office or distributor serving you.
SILICA, Ultra High Range,
continued
Summary of Contents for DR/850
Page 2: ...2...
Page 8: ...8...
Page 9: ...9 Sample Procedure Explained...
Page 10: ...10 Sample Procedure Explained continued...
Page 11: ...11 Sample Procedure Explained continued...
Page 12: ...12 Sample Procedure Explained continued...
Page 41: ...41 CHEMICAL ANALYSIS INFORMATION continued Figure 10 Multiple Standard Additions Graph...
Page 69: ...69 SECTION 4 PROCEDURES...
Page 70: ...70...
Page 92: ...92...
Page 100: ...100...
Page 108: ...108...
Page 116: ...116...
Page 139: ...139...
Page 140: ...140...
Page 168: ...168...
Page 176: ...176...
Page 184: ...184...
Page 194: ...194...
Page 202: ...202...
Page 214: ...214...
Page 234: ...234...
Page 242: ...242...
Page 264: ...264...
Page 270: ...270...
Page 284: ...284...
Page 298: ...298...
Page 314: ...314...
Page 324: ...324...
Page 332: ...332...
Page 336: ...336...
Page 340: ...340...
Page 354: ...354...
Page 370: ...370...
Page 378: ...378...
Page 386: ...386...
Page 398: ...398...
Page 404: ...404...
Page 412: ...412...
Page 424: ...424...
Page 436: ...436...
Page 446: ...446...
Page 456: ......
Page 459: ......
Page 460: ...460...