168
The current system time and date are decided by the
clock datetime
,
clock summer-
time one-off
(or
clock summer-time repeating
),
clock timezone
. For more information
about the rules, see
Basic System Configuration
in the
Fundamentals Configuration
Guide
.
Related commands:
clock datetime
,
clock summer-time one-off
,
clock summer-time
repeating
, and
clock timezone
.
Examples
Display the current time and date.
<Sysname> display clock
09:41:23 UTC Thu 12/15/2005
display configure-user
Syntax
display configure-user
View
Any view
Default Level
1: Monitor level
Parameters
None
Description
Use the
display configure-user
command to display the users that have logged in to
the AC and are not in user view.
Related commands:
configure-user count
.
Examples
Display the users entering system view at the same time.
<Sysname> display configure-user
The information of current configuration user(s):
Idx UI Delay Type Userlevel
+ 1 VTY 0 01:10:16 TEL 3
+ 2 VTY 1 00:00:00 TEL 3
Following are more details.
VTY 0 :
User name: admin
Location: 192.168.1.59
VTY 1 :
User name: admin